Peterson Jeffrey R, Blieden Lauren S, Chuang Alice Z, Baker Laura A, Rigi Mohammed, Feldman Robert M, Bell Nicholas P
Ruiz Department of Ophthalmology and Visual Science, The University of Texas Health Science Center at Houston (UTHealth) McGovern Medical School, Houston, Texas, United States of America.
Robert Cizik Eye Clinic, Houston, Texas, United States of America.
PLoS One. 2016 Jan 27;11(1):e0147760. doi: 10.1371/journal.pone.0147760. eCollection 2016.
Define criteria for iris-related parameters in an adult open angle population as measured with swept source Fourier domain anterior segment optical coherence tomography (ASOCT).
Ninety-eight eyes of 98 participants with open angles were included and stratified into 5 age groups (18-35, 36-45, 46-55, 56-65, and 66-79 years). ASOCT scans with 3D mode angle analysis were taken with the CASIA SS-1000 (Tomey Corporation, Nagoya, Japan) and analyzed using the Anterior Chamber Analysis and Interpretation software. Anterior iris surface length (AISL), length of scleral spur landmark (SSL) to pupillary margin (SSL-to-PM), iris contour ratio (ICR = AISL/SSL-to-PM), pupil radius, radius of iris centroid (RICe), and iris volume were measured. Outcome variables were summarized for all eyes and age groups, and mean values among age groups were compared using one-way analysis of variance. Stepwise regression analysis was used to investigate demographic and ocular characteristic factors that affected each iris-related parameter.
Mean (±SD) values were 2.24 mm (±0.46), 4.06 mm (±0.27), 3.65 mm (±0.48), 4.16 mm (±0.47), 1.14 (±0.04), 1.51 mm2 (±0.23), and 38.42 μL (±4.91) for pupillary radius, RICe, SSL-to-PM, AISL, ICR, iris cross-sectional area, and iris volume, respectively. Both pupillary radius (P = 0.002) and RICe (P = 0.027) decreased with age, while SSL-to-PM (P = 0.002) and AISL increased with age (P = 0.001). ICR (P = 0.54) and iris volume (P = 0.49) were not affected by age.
This study establishes reference values for iris-related parameters in an adult open angle population, which will be useful for future studies examining the role of iris changes in pathologic states.
定义使用扫频源傅里叶域眼前节光学相干断层扫描(ASOCT)测量的成人开角人群中与虹膜相关参数的标准。
纳入98名开角参与者的98只眼睛,并将其分为5个年龄组(18 - 35岁、36 - 45岁、46 - 55岁、56 - 65岁和66 - 79岁)。使用CASIA SS - 1000(日本名古屋Tomey公司)进行具有3D模式角度分析的ASOCT扫描,并使用眼前房分析与解释软件进行分析。测量前虹膜表面长度(AISL)、巩膜突标志(SSL)至瞳孔边缘的长度(SSL - 至 - PM)、虹膜轮廓比(ICR = AISL/SSL - 至 - PM)、瞳孔半径、虹膜质心半径(RICe)和虹膜体积。总结所有眼睛和年龄组的结果变量,并使用单因素方差分析比较年龄组之间的平均值。采用逐步回归分析来研究影响每个与虹膜相关参数的人口统计学和眼部特征因素。
瞳孔半径、RICe、SSL - 至 - PM、AISL、ICR、虹膜横截面积和虹膜体积的平均值(±标准差)分别为2.24 mm(±0.46)、4.06 mm(±0.27)、3.65 mm(±0.48)、4.16 mm(±0.47)、1.14(±0.04)、1.51 mm²(±0.23)和38.42 μL(±4.91)。瞳孔半径(P = 0.002)和RICe(P = 0.027)均随年龄增长而减小,而SSL - 至 - PM(P = 0.002)和AISL随年龄增长而增加(P = 0.001)。ICR(P = 0.54)和虹膜体积(P = 0.49)不受年龄影响。
本研究建立了成人开角人群中与虹膜相关参数的参考值,这将有助于未来研究检查虹膜变化在病理状态中的作用。