Xu Yiwei, Zhang Wen, Shi Jiyong, Zou Xiaobo, Li Zhihua, Zhu Yaodi
College of Food and Biological Engineering, Jiangsu University, Zhenjiang 212013, China.
College of Food and Biological Engineering, Jiangsu University, Zhenjiang 212013, China.
Food Chem. 2016 Jun 15;201:190-6. doi: 10.1016/j.foodchem.2016.01.078. Epub 2016 Jan 20.
An in-situ plating bismuth modified interdigitated Au electrode (IAE) was developed for determination of Pb(2+) and Cd(2+) in crab. The IAE was fabricated and used as counter electrode and working electrode. Cyclic voltammetry (CV) was performed with the IAE for studying electrochemical performance, showing clear redox peaks. The key operational parameters were optimized, which were 600 μg L(-1) of Bi(3+) concentration, 0.1 mol L(-1) of acetate buffer (pH 4.5), -1.2V of deposition potential and 180 s of deposition time. Under optimized condition, the linear range of IAE was from 5 to 50 μg L(-1) for both metal ions, with detection limit (threefold signal-to-noise) of 0.74 μg L(-1) for Pb(2+) and 0.86 μg L(-1) for Cd(2+). Finally, the developed sensor was applied to detect Pb(2+) and Cd(2+) in crab extract solutions by standard addition method. The results were in good agreement with outcomes obtained by inductively coupled plasma mass spectrometry.
开发了一种原位镀铋修饰的叉指金电极(IAE)用于测定螃蟹中的Pb(2+)和Cd(2+)。制备了IAE并将其用作对电极和工作电极。用IAE进行循环伏安法(CV)研究其电化学性能,显示出明显的氧化还原峰。优化了关键操作参数,即Bi(3+)浓度为600 μg L(-1)、醋酸盐缓冲液(pH 4.5)为0.1 mol L(-1)、沉积电位为-1.2V、沉积时间为180 s。在优化条件下,两种金属离子在IAE上的线性范围均为5至50 μg L(-1),Pb(2+)的检测限(三倍信噪比)为0.74 μg L(-1),Cd(2+)的检测限为0.86 μg L(-1)。最后,采用标准加入法将所开发的传感器应用于检测螃蟹提取液中的Pb(2+)和Cd(2+)。结果与电感耦合等离子体质谱法获得的结果高度一致。