Suppr超能文献

环保型纳米复合碳糊电极在实际样品中 Cd(II)伏安法测定的最新进展。

Recent development of eco-friendly nanocomposite carbon paste electrode for voltammetric determination of Cd(II) in real samples.

机构信息

Chemistry Department, Faculty of Science, Minia University, Minia, 61511, Egypt.

出版信息

Anal Sci. 2023 Feb;39(2):179-190. doi: 10.1007/s44211-022-00214-3. Epub 2022 Nov 19.

Abstract

Using eco-friendly, cheap, and available adsorbents is promising for the determination of metal ions. So, this study focuses on the modification of graphite reinforcement carbon paste electrode (GRCPE) with mango seed kernel (MSK) for voltammetric determination of Cd(II). Moreover, to increase the surface area of this adsorbent, it was prepared in nanosized that formed nanoparticles of mango seed kernel (MSK-NPs). The developed nanocomposite electrode of carbon paste electrode modified with nanoparticles of mango seed kernel (MSK-NPs@GRCPE) was characterized using Fourier transform infrared (FTIR) and Scanning electron microscopy (SEM). The effect of pH, buffer solution, and supporting electrolyte as experimental conditions were optimized through differential pulse adsorptive anodic stripping voltammetric method (DPAASV). Britton-Robinson buffer pH = 3.9 at E = - 1400 mV, t = 30 s, pulse width = 10 ms and sampling time = 8 ms were the optimum conditions for determination of Cd(II). The LOD and LOQ of MSK-NPs@GRCPE were calculated at 5.44 × 10 and 1.65 × 10 M, respectively. Compared with bare graphite reinforcement carbon paste electrode (BGRCPE), the nanocomposite MSK-NPs@GRCPE has a lower detection limit, indicating that the presence of MSK-NPs could greatly improve the response to Cd(II). The practical applicability of the electrode was verified by the determination of Cd(II) in chocolate and white rice samples. The results show high selectivity and sensitivity for Cd(II) in real samples.

摘要

使用环保、廉价且易得的吸附剂来测定金属离子具有广阔的前景。因此,本研究专注于用芒果种子(MSK)修饰石墨增强碳糊电极(GRCPE),以用于 Cd(II) 的伏安法测定。此外,为了增加该吸附剂的表面积,将其制备成纳米级,形成芒果种子纳米颗粒(MSK-NPs)。采用傅里叶变换红外(FTIR)和扫描电子显微镜(SEM)对制备的碳糊电极纳米复合材料进行了表征。通过差分脉冲吸附阳极溶出伏安法(DPAASV)优化了 pH 值、缓冲溶液和支持电解质等实验条件。在 pH=3.9 的 Britton-Robinson 缓冲溶液中,E=-1400 mV,t=30 s,脉冲宽度=10 ms,采样时间=8 ms 是测定 Cd(II)的最佳条件。MSK-NPs@GRCPE 的检出限和定量限分别为 5.44×10-9 和 1.65×10-9 M。与裸石墨增强碳糊电极(BGRCPE)相比,纳米复合材料 MSK-NPs@GRCPE 的检测限更低,表明 MSK-NPs 的存在可以大大提高对 Cd(II)的响应。通过对巧克力和白米样品中 Cd(II)的测定,验证了该电极的实际适用性。结果表明,该电极对实际样品中的 Cd(II)具有高选择性和灵敏度。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/a527/10082124/90a596062b54/44211_2022_214_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验