Sabouhi Mahmoud, Bajoghli Farshad, Dakhilalian Mansour, Beygi Ali, Abolhasani Majid
*Assistant Professor, Dental Materials Research Center, Department of Prosthodontics, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran. †Associate Professor, Dental Implants Research Center, Department of Prosthodontics, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran. ‡Assistant Professor, Dental Implants Research Center, Department of Prosthodontics, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran. §Postgraduate Student, Dental Students Research Center, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran.
Implant Dent. 2016 Apr;25(2):238-46. doi: 10.1097/ID.0000000000000389.
The aim of this in vitro study was to evaluate the effect of the type and design of the impression copings on the accuracy of implant impressions in 2 different conditions.
A reference model with 2 implants inserted in bilateral mandibular canines was fabricated. The posterior teeth were inserted as tilted to simulate intra-oral undercuts. The teeth were eliminated to create an edentulous condition. Three different impression techniques were performed (open high retentive [OH], open low retentive [OL], closed [C]) for each condition. Total of 48 casts were made. Two scan-bodies were secured on each cast, scanned by an optical scanner. Then, they were compared to the scan of the reference model, and the calculated mean errors were analyzed with a 2-way ANOVA and Tukey test.
There was no significant difference between the complete and partially edentulous groups (F = 3.252, P = 0.079). There was significant difference between the different designs of the impression copings (F = 31.789, P < 0.001) but the interaction between the dependent variables was not significant (F = 0.511, P = 0.603).
The design of the impression copings was more important than the undercuts. The accuracy of the closed tray coping was greater than the low retentive coping and equal to the high retentive coping.
本体外研究的目的是评估印模帽的类型和设计在两种不同条件下对种植体印模准确性的影响。
制作一个双侧下颌尖牙植入两颗种植体的参考模型。将后牙倾斜插入以模拟口腔内倒凹。去除牙齿以形成无牙状态。每种条件下采用三种不同的印模技术(开放式高固位[OH]、开放式低固位[OL]、封闭式[C])。共制作了48个模型。在每个模型上固定两个扫描体,用光学扫描仪进行扫描。然后,将它们与参考模型的扫描结果进行比较,计算出的平均误差采用双向方差分析和Tukey检验进行分析。
全口无牙组和部分无牙组之间无显著差异(F = 3.252,P = 0.079)。印模帽的不同设计之间存在显著差异(F = 31.789,P < 0.001),但因变量之间的交互作用不显著(F = 0.511,P = 0.603)。
印模帽的设计比倒凹更重要。封闭式托盘印模帽的准确性高于低固位印模帽,与高固位印模帽相当。