In vitro removal of anti-A and anti-B antibodies by immunoadsorbents with synthetic oligosaccharide structures representing blood group substances have been studied under controlled and simulated extracorporeal perfusion conditions at different flow rates ranging from 20 to 160 mL/min. There is a gradual decline in antibody titers in the plasma, as it relates to the antibody binding capacity and efficiency of the immunoadsorbents, both as a function of time and plasma volume at any of the flow rates employed. Approximately the same maximal binding capacity is achieved in about 4 hours of perfusion regardless of the flow rate, whereas increased number of plasma volumes are required at higher flow rates to compensate for the appropriate residence times needed in the column to utilize the same capacity. The perfusion time alone appears to be a critical factor which via the flow rate determines the residence time between the plasma and the immobilized hapten in the column. Also, the optimal flow rate at which maximum binding capacity of the immunoadsorbent may be utilized efficiently appears to fall within a range of the flow rate. The factors determining this range and the efficiency of the immunoadsorbents under dynamic conditions are discussed. The results obtained under the controlled conditions and the discussions that follow are expected to be generally useful, at least, as approximate clinical guidelines, for selective removal of specific substances by extracorporeal perfusion techniques utilizing therapeutic intervention with immunoadsorbents in this important area of medical therapy.
在20至160 mL/分钟的不同流速下,于受控和模拟的体外灌注条件下,研究了用具有代表血型物质的合成寡糖结构的免疫吸附剂体外去除抗A和抗B抗体的情况。血浆中抗体滴度逐渐下降,这与免疫吸附剂的抗体结合能力和效率有关,且在所用的任何流速下,均是时间和血浆量的函数。无论流速如何,在灌注约4小时后均可达到大致相同的最大结合能力,而在较高流速下需要增加血浆量,以补偿柱中利用相同能力所需的适当停留时间。单独的灌注时间似乎是一个关键因素,它通过流速决定血浆与柱中固定化半抗原之间的停留时间。此外,能有效利用免疫吸附剂最大结合能力的最佳流速似乎落在一定的流速范围内。讨论了决定该范围的因素以及动态条件下免疫吸附剂的效率。在受控条件下获得的结果以及随后的讨论预计至少作为大致的临床指南,对于在这一重要医学治疗领域中利用免疫吸附剂进行治疗干预的体外灌注技术选择性去除特定物质通常是有用的。