Comparison of effect between high intense focused ultrasound devices for facial tightening: Evaluator-blinded, split-face study.

作者信息

Jung Ho Joo, Min Jung, Seo Hyun-Min, Kim Won-Serk

机构信息

a Department of Dermatology , Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine , Seoul , Korea.

出版信息

J Cosmet Laser Ther. 2016 Oct;18(5):252-6. doi: 10.3109/14764172.2016.1157359. Epub 2016 Apr 21.

Abstract

BACKGROUND

Various high intense focused ultrasound (HIFU) devices have been introduced in recent years for improving skin laxity, with satisfactory results. However, there is no comparative study on the efficacy and safety of available HIFU devices.

OBJECTIVE

To compare the efficacy and safety of two HIFU devices for facial skin tightening and subsequently, to validate the quantitative assessment.

METHODS AND MATERIALS

We performed a split-face comparative study in 20 Korean patients. Two different HIFU devices were used on each side of the face. Patients received one treatment session on the same number of coagulative zones. Patient assessments were recorded. Three blinded clinicians evaluated paired pretreatment and post-treatment photographs. Quantitative assessment using a fixed point as well as a variable point was additionally performed for objective evaluation.

RESULTS

Qualitative assessments of both HIFU devices conducted by both clinicians and patients generally showed mild to moderate improvement, similar to previous studies. The two devices had similar efficacy in blinded clinician and quantitative assessment, although there were some differences in patient satisfaction and degree of pain. There was a correlation between clinician qualitative scores and quantitative values, which suggests successful skin tightening.

CONCLUSION

To the author's knowledge, both HIFU devices tested can be used safely and effectively for facial tightening.

摘要

背景

近年来,各种高强度聚焦超声(HIFU)设备已被引入用于改善皮肤松弛,效果令人满意。然而,对于现有HIFU设备的疗效和安全性尚无比较研究。

目的

比较两种HIFU设备对面部皮肤紧致的疗效和安全性,并随后验证定量评估。

方法和材料

我们对20名韩国患者进行了一项半脸对照研究。在面部两侧使用两种不同的HIFU设备。患者在相同数量的凝固区接受一次治疗。记录患者评估情况。三名不知情的临床医生评估配对的治疗前和治疗后照片。另外还使用固定点和可变点进行定量评估以进行客观评价。

结果

临床医生和患者对两种HIFU设备的定性评估总体上显示出轻度至中度改善,与先前的研究相似。尽管在患者满意度和疼痛程度上存在一些差异,但两种设备在不知情临床医生的评估和定量评估中具有相似的疗效。临床医生的定性评分与定量值之间存在相关性,这表明皮肤紧致成功。

结论

据作者所知,所测试的两种HIFU设备均可安全有效地用于面部紧致。