• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

An accurate exercise lead system for bicycle ergometer tests.

作者信息

Edenbrandt L, Pahlm O, Sörnmo L

机构信息

Department of Clinical Physiology, University of Lund, Sweden.

出版信息

Eur Heart J. 1989 Mar;10(3):268-72. doi: 10.1093/oxfordjournals.eurheartj.a059475.

DOI:10.1093/oxfordjournals.eurheartj.a059475
PMID:2707274
Abstract

In order to minimize muscle noise in the exercise electrocardiogram, Mason and Likar proposed a new lead system where the limb electrodes are instead placed on the trunk. The Mason-Likar system is widely used for both the resting ECG before exercise and recordings during exercise. Several studies have, however, reported great differences between this lead system and the standard lead system. This study shows greater R wave amplitudes in leads II, aVF and III, smaller R wave amplitudes in leads aVL and I and thus a vertical shift of the frontal plane QRS axis for the Mason-Likar system compared with the standard system. For many years another lead system for exercise tests with the bicycle ergometer has been used in our laboratory. The limb electrodes are placed at the proximal part of the arms and the left iliac crest. This lead system yields ECG signals with a low level of muscle noise. The differences between this lead system and the standard ECG are much less pronounced than the differences between the Mason-Likar ECG and standard ECG. We propose our lead system for exercise tests with the bicycle ergometer.

摘要

相似文献

1
An accurate exercise lead system for bicycle ergometer tests.
Eur Heart J. 1989 Mar;10(3):268-72. doi: 10.1093/oxfordjournals.eurheartj.a059475.
2
Fundamental differences between the standard 12-lead electrocardiograph and the modified (Mason-Likar) exercise lead system.
Eur Heart J. 1987 Jul;8(7):725-33. doi: 10.1093/eurheartj/8.7.725.
3
Effects of limb electrode placement on the 12- and 16-lead electrocardiogram.肢体电极放置对12导联和16导联心电图的影响。
J Electrocardiol. 2008 Nov-Dec;41(6):536-45. doi: 10.1016/j.jelectrocard.2008.07.023. Epub 2008 Sep 13.
4
[Problems of Mason-Likar lead system in treadmill exercise electrocardiography].
Rinsho Byori. 1991 Aug;39(8):846-52.
5
Comparison of EASI-derived 12-lead electrocardiograms versus paramedic-acquired 12-lead electrocardiograms using Mason-Likar limb lead configuration in patients with chest pain.在胸痛患者中,使用梅森-利卡尔肢体导联配置比较基于快速皮肤阻抗测量(EASI)得出的12导联心电图与护理人员采集的12导联心电图。
J Electrocardiol. 2006 Jan;39(1):13-21. doi: 10.1016/j.jelectrocard.2005.05.011. Epub 2005 Nov 9.
6
Comparison of signal quality between EASI and Mason-Likar 12-lead electrocardiograms during physical activity.运动期间EASI与Mason-Likar 12导联心电图信号质量的比较。
Am J Crit Care. 2004 May;13(3):228-34.
7
Correct utilization of exercise electrocardiographic leads in differentiation of men with coronary artery disease from patients with a low likelihood of coronary artery disease using peak exercise ST-segment depression.
Am J Cardiol. 1998 Apr 15;81(8):964-9. doi: 10.1016/s0002-9149(98)00073-3.
8
An alternative limb lead system for electrocardiographs in emergency patients.一种用于急诊患者心电图仪的替代肢体导联系统。
Am J Emerg Med. 1995 Sep;13(5):514-7. doi: 10.1016/0735-6757(95)90160-4.
9
The 12-lead electrocardiogram in exercise testing. A misleading baseline?
Arch Intern Med. 1978 Oct;138(10):1572-3.
10
QRS scoring with the Mason-Likar lead system at rest and during ischaemia.采用Mason-Likar导联系统在静息和缺血期间进行QRS评分。
Clin Physiol. 1991 Sep;11(5):423-30. doi: 10.1111/j.1475-097x.1991.tb00814.x.

引用本文的文献

1
Modified torso vs distal limb electrode placement for performing ECGs in children: A method comparison study.儿童心电图检查中改良躯干电极与远端肢体电极放置的比较:一项方法对比研究。
J Electrocardiol. 2024 Nov-Dec;87:153810. doi: 10.1016/j.jelectrocard.2024.153810. Epub 2024 Sep 24.
2
Modified limb lead ECG system effects on electrocardiographic wave amplitudes and frontal plane axis in sinus rhythm subjects.改良肢体导联心电图系统对窦性心律受试者心电图波幅及额面电轴的影响。
Anatol J Cardiol. 2017 Jan;17(1):46-54. doi: 10.14744/AnatolJCardiol.2016.6843. Epub 2016 Jun 29.
3
Normal limits of ECG measurements related to atrial activity using a modified limb lead system.
使用改良肢体导联系统测量与心房活动相关的心电图的正常范围。
Anatol J Cardiol. 2015 Jan;15(1):2-6. doi: 10.5152/akd.2014.5155. Epub 2014 Feb 26.
4
Modified electrode placement must be recorded when performing 12-lead electrocardiograms.在进行12导联心电图检查时,必须记录改良后的电极放置位置。
Postgrad Med J. 2005 Feb;81(952):122-5. doi: 10.1136/pgmj.2004.021204.