Suppr超能文献

压电植入部位制备中的温度值变异性:皮质骨和皮质松质牛骨之间的差异

Temperature Values Variability in Piezoelectric Implant Site Preparation: Differences between Cortical and Corticocancellous Bovine Bone.

作者信息

Lamazza Luca, Garreffa Girolamo, Laurito Domenica, Lollobrigida Marco, Palmieri Luigi, De Biase Alberto

机构信息

Department of Oral and Maxillofacial Sciences, Sapienza University of Rome, 00161 Rome, Italy.

Euro-Mediterranean Institute of Science and Technology, 90139 Palermo, Italy; Me. Di. Mediterranea Diagnostica, 80053 Castellammare di Stabia, Italy.

出版信息

Biomed Res Int. 2016;2016:6473680. doi: 10.1155/2016/6473680. Epub 2016 Mar 24.

Abstract

PURPOSE

Various parameters can influence temperature rise and detection during implant site preparation. The aim of this study is to investigate local temperature values in cortical and corticocancellous bovine bone during early stages of piezoelectric implant site preparation.

MATERIALS AND METHODS

20 osteotomies were performed using a diamond tip (IM1s, Mectron Medical Technology, Carasco, Italy) on two different types of bovine bone samples, cortical and corticocancellous, respectively. A standardized protocol was designed to provide constant working conditions. Temperatures were measured in real time at a fixed position by a fiber optic thermometer.

RESULTS

Significantly higher drilling time (154.90 sec versus 99.00 sec; p < 0.0001) and temperatures (39.26°C versus 34.73°C; p = 0.043) were observed in the cortical group compared to the corticocancellous group. A remarkable variability of results characterized the corticocancellous blocks as compared to the blocks of pure cortical bone.

CONCLUSION

Bone samples can influence heat generation during in vitro implant site preparation. When compared to cortical bone, corticocancellous samples present more variability in temperature values. Even controlling most experimental factors, the impact of bone samples still remains one of the main causes of temperature variability.

摘要

目的

在种植体植入部位预备过程中,多种参数会影响温度升高及检测结果。本研究旨在探究压电式种植体植入部位预备早期皮质骨和皮质骨松质骨中的局部温度值。

材料与方法

分别在两种不同类型的牛骨样本(皮质骨和皮质骨松质骨)上使用金刚石钻头(IM1s,Mectron Medical Technology,意大利卡拉斯科)进行20次截骨术。设计了标准化方案以提供恒定的工作条件。通过光纤温度计在固定位置实时测量温度。

结果

与皮质骨松质骨组相比,皮质骨组的钻孔时间显著更长(154.90秒对99.00秒;p < 0.0001),温度也更高(39.26°C对34.73°C;p = 0.043)。与纯皮质骨块相比,皮质骨松质骨块的结果具有显著的变异性。

结论

骨样本会影响体外种植体植入部位预备过程中的产热。与皮质骨相比,皮质骨松质骨样本的温度值变异性更大。即使控制了大多数实验因素,骨样本的影响仍然是温度变异性的主要原因之一。