Suppr超能文献

用于矫正高度近视的可植入式胶原晶状体V4b和V4c

Implantable collamer lens V4b and V4c for correction of high myopia.

作者信息

Bhandari Vipul, Karandikar Smitha, Reddy Jagdeesh K, Relekar Kirti

机构信息

Sankara Eye Center, Sivanadapuram, Sathy Road, Coimbatore, India.

出版信息

J Curr Ophthalmol. 2016 Feb 9;27(3-4):76-81. doi: 10.1016/j.joco.2016.01.001. eCollection 2015 Sep-Dec.

Abstract

PURPOSE

To evaluate the visual outcome and intraocular pressure changes after Visian Implantable Collamer Lens (ICL) implantation V4b and V4c (with central hole) for correction of high myopia.

METHODS

A prospective, consecutive, interventional comparative case series of V4b and V4c ICL implantation was done in high myopic patients who were unsuitable for laser vision. The main outcome measures studied were uncorrected and corrected distant visual acuity (UDVA, CDVA), ICL vault, intraocular pressure (IOP), endothelial cell count (ECC), and development of subcapsular lens opacities. The patients were evaluated at postoperative 1,3,6, and 9 months.

RESULTS

A total of 62 eyes of 32 patients (24.56 ± 4.8 years) underwent V4b ICL implantation (21 non-toric, 41 toric ICL-TICL) with intraoperative peripheral iridectomy (PI), and 10 eyes of 5 patients (26.13 ± 3.8 years) had implantation of V4c ICL (4 non-toric, 6 TICL). The mean preoperative manifest spherical equivalent (MSE) was -9.98 ± 2.8 D and -9.14 ± 2.4 D in the V4b and V4c groups, respectively, which reduced to postoperative values of -0.24 ± 1.3 D and -0.2 ± 1.18 D, respectively. At the end of 9 months follow-up, mean ECC loss was 6.4% and 6.1%, mean vault was 573.13 ± 241.13 μ, and 612 ± 251.14 μ, respectively, in the V4b and V4c groups. Anterior subcapsular opacities were present in 6.9% and 3.14% of eyes with V4b and V4c groups, respectively. Four eyes from V4b (9.75%) and 1 eye from V4c (16.66%) had rotation of more than 30° and required realignment surgery, which was done successfully. Two eyes (3.22%) with V4b ICL implantation had high postoperative IOP (>35 mm Hg) due to blocked PI and required Nd:Yag laser iridotomy, which was done with successful control of IOP. The safety indices were 1.11 and 1.14, and efficacy indices were 1.4 and 1.5 in the V4b and V4c groups, respectively, at the end of 9 months.

CONCLUSION

ICL implantation is a safe and effective surgery for correction of high myopia. Implantation of ICL with a central hole showed negligible postoperative IOP fluctuations without a peripheral iridectomy.

摘要

目的

评估植入Visian可植入式胶原晶状体(ICL)V4b和V4c(带中心孔)矫正高度近视后的视觉效果和眼压变化。

方法

对不适合激光视力矫正的高度近视患者进行V4b和V4c ICL植入的前瞻性、连续、干预性对比病例系列研究。研究的主要结局指标为未矫正和矫正远视力(UDVA、CDVA)、ICL拱高、眼压(IOP)、内皮细胞计数(ECC)以及晶状体后囊下混浊的发生情况。在术后1、3、6和9个月对患者进行评估。

结果

32例患者(24.56±4.8岁)的62只眼接受了V4b ICL植入(21只非散光型,41只散光型ICL-TICL),术中进行了周边虹膜切除术(PI);5例患者(26.13±3.8岁)的10只眼植入了V4c ICL(4只非散光型,6只TICL)。V4b组和V4c组术前平均等效球镜度(MSE)分别为-9.98±2.8 D和-9.14±2.4 D,术后分别降至-0.24±1.3 D和-0.2±1.18 D。在9个月随访结束时,V4b组和V4c组的平均ECC损失分别为6.4%和6.1%,平均拱高分别为573.13±241.13μm和612±251.14μm。V4b组和V4c组分别有6.9%和3.14%的眼出现前囊下混浊。V4b组有4只眼(9.75%)和V4c组有1只眼(16.66%)发生了超过30°的旋转,需要进行重新定位手术,手术成功完成。2只接受V4b ICL植入的眼(3.22%)因PI阻塞术后眼压升高(>35 mmHg),需要进行Nd:YAG激光虹膜切开术,眼压得到成功控制。在9个月结束时,V4b组和V4c组的安全指数分别为1.11和1.14,疗效指数分别为1.4和1.5。

结论

ICL植入是矫正高度近视的一种安全有效的手术。植入带中心孔的ICL在不进行周边虹膜切除术的情况下,术后眼压波动可忽略不计。