Suppr超能文献

圆锥角膜中角膜和眼前节参数的变异性。

The variability of corneal and anterior segment parameters in keratoconus.

作者信息

Mas-Aixala Enric, Gispets Joan, Lupón Núria, Cardona Genís

机构信息

Technical University of Catalonia, Faculty of Optics and Optometry, Optics and Optometry Department, c/Violinista Vellsolà, 37, E08222, Terrassa, Spain.

Technical University of Catalonia, Faculty of Optics and Optometry, Optics and Optometry Department, c/Violinista Vellsolà, 37, E08222, Terrassa, Spain.

出版信息

Cont Lens Anterior Eye. 2016 Dec;39(6):466-470. doi: 10.1016/j.clae.2016.05.003. Epub 2016 Jun 1.

Abstract

PURPOSE

To analyse, describe and test diverse corneal and anterior segment parameters in normal and keratoconic eyes to better understand the geometry of the keratoconic cornea.

METHOD

44 eyes from 44 keratoconic patients and 44 eyes from 44 healthy patients were included in the study. The Pentacam System was used for the analysis of the anterior segment parameters. New ad-hoc parameters were defined by measuring the distances on the Scheimpflug image at the horizontal diameter, with chamber depth now comprising of two distinctive distances: corneal sagittal depth and the distance from the endpoint of this segment to the anterior surface of the lens (DL).

RESULTS

Statistically significant differences (p<0.05) between normal and keratoconic eyes were found in all of the analysed corneal parameters. Anterior chamber depth presented statistical differences between normal and keratoconic eyes (3.06±0.43mm versus 3.34±0.45mm, respectively; p=0.004). This difference was found to originate in an increase of the DL distance (0.40±0.33mm in normal eyes against 0.61±0.45mm in keratoconic eyes; p=0.014), rather than in the changes in corneal sagittal depth.

CONCLUSION

These findings indicate that keratoconus results in central and peripheral corneal manifestations, as well as changes in the shape of the scleral limbus. The DL parameter was useful in describing the forward elongation and advance of the scleral tissue in keratoconic eyes. This finding may help in the monitoring of disease progression and contact lens design and fitting.

摘要

目的

分析、描述和测试正常眼和圆锥角膜眼的各种角膜及眼前节参数,以更好地了解圆锥角膜的几何形态。

方法

本研究纳入了44例圆锥角膜患者的44只眼和44例健康患者的44只眼。使用Pentacam系统分析眼前节参数。通过在水平直径处的Scheimpflug图像上测量距离来定义新的特定参数,前房深度现在由两个不同的距离组成:角膜矢状深度以及该段端点到晶状体前表面的距离(DL)。

结果

在所有分析的角膜参数中,正常眼和圆锥角膜眼之间存在统计学显著差异(p<0.05)。正常眼和圆锥角膜眼的前房深度存在统计学差异(分别为3.06±0.43mm和3.34±0.45mm;p = 0.004)。发现这种差异源于DL距离的增加(正常眼为0.40±0.33mm,圆锥角膜眼为0.61±0.45mm;p = 0.014),而非角膜矢状深度的变化。

结论

这些发现表明圆锥角膜会导致角膜中央和周边的表现,以及巩膜缘形状的改变。DL参数有助于描述圆锥角膜眼中巩膜组织的向前伸长和前移。这一发现可能有助于监测疾病进展以及隐形眼镜的设计和适配。