Suppr超能文献

基质内角膜环段植入术后圆锥角膜患者前、后角膜参数的变化。

Changes in anterior and posterior corneal parameters in patients with keratoconus after intrastromal corneal-ring segment implantation.

机构信息

Department of Ophthalmology and Visual Science, Daejeon St. Mary's Hospital and Catholic University of Korea, Seoul, Korea.

出版信息

Curr Eye Res. 2013 Aug;38(8):843-50. doi: 10.3109/02713683.2013.788723. Epub 2013 Apr 22.

Abstract

PURPOSE

To compare changes in the anterior and the posterior corneal parameters and the anterior chamber depth (ACD) measured by a rotating Scheimpflug camera and scanning-slit topography before and after intrastromal corneal ring segment (ICRS) implantation.

METHODS

Twenty-five eyes of 21 keratoconus patients who had Intacs (Addition Technology, Sunnyvale, CA) ICRS implantation were included. The anterior segment parameters of the participants were measured before and 3 months after Intacs ICRS implantation with a rotating Scheimpflug camera and scanning-slit topography. Outcome measures included uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction and corneal topography.

RESULTS

The UDVA improved in 21 eyes (84%) and CDVA in 18 eyes (72%). The anterior average keratometry decreased from 51.80 D preoperatively to 49.59 D postoperatively (p < 0.001) using the rotating Scheimpflug camera and Sim K decreased from 51.21 to 47.44 D using the scanning-slit topography. The posterior average keratometry decreased from -8.03 D preoperatively to -8.42 D postoperatively (p < 0.001) using the rotating Scheimpflug camera. ACD decreased from 3.44 to 3.32 mm (p < 0.001) and from 3.28 to 3.19 mm (p < 0.001) using the rotating Scheimpflug camera and scanning-slit topography, respectively.

CONCLUSIONS

The implantation of Intacs segments induced corneal flattening of the anterior surface and corneal steepening of the posterior surface. Both anterior corneal flattening and posterior corneal steepening contributed to the decrease in the keratometric power.

摘要

目的

比较旋转式 Scheimpflug 相机和扫描 slit topography 测量角膜基质内环段(ICRS)植入前后前、后角膜参数和前房深度(ACD)的变化。

方法

纳入 21 例 25 眼圆锥角膜患者,均行 Intacs(Addition Technology,加利福尼亚州森尼韦尔)ICRS 植入术。采用旋转式 Scheimpflug 相机和扫描 slit topography 分别于 Intacs ICRS 植入术前和术后 3 个月测量患者眼前节参数。观察指标包括未矫正(UDVA)和矫正(CDVA)远视力、屈光度和角膜地形图。

结果

21 只眼(84%)的 UDVA 提高,18 只眼(72%)的 CDVA 提高。旋转式 Scheimpflug 相机测量的平均角膜曲率从术前的 51.80 D 下降至术后的 49.59 D(p<0.001),Sim K 值从术前的 51.21 下降至术后的 47.44 D;扫描 slit topography 测量的平均角膜曲率从术前的-8.03 D 下降至术后的-8.42 D(p<0.001)。旋转式 Scheimpflug 相机测量的 ACD 从术前的 3.44 mm 下降至术后的 3.32 mm(p<0.001),从术前的 3.28 mm 下降至术后的 3.19 mm(p<0.001)。

结论

Intacs 段的植入导致前表面角膜变平,后表面角膜变陡。前角膜变平和后角膜变陡都导致了角膜屈光度的降低。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验