Suppr超能文献

使用Pentacam系统测量圆锥角膜眼眼前节参数的评估

Evaluation of anterior segment parameters in keratoconic eyes measured with the Pentacam system.

作者信息

Emre Sinan, Doganay Selim, Yologlu Saim

机构信息

Department of Ophthalmology, School of Medicine, Inonu University, Malatya, Turkey.

出版信息

J Cataract Refract Surg. 2007 Oct;33(10):1708-12. doi: 10.1016/j.jcrs.2007.06.020.

Abstract

PURPOSE

To evaluate the alteration in anterior chamber parameters with the progression of keratoconus using a rotating Scheimpflug camera.

SETTING

Inonu University, Turgut Ozal Medical Center, Ophthalmology Department, Malatya, Turkey.

METHODS

Two hundred sixteen eyes of 123 patients diagnosed with keratoconus and 224 eyes of 112 normal subjects were evaluated with a Pentacam Scheimpflug camera (Oculus Inc.). Keratoconic eyes were divided into 3 groups according to mean keratometer (K) readings: mild (K = less than 47.0 diopters [D]), moderate (K = 47.0 to 52.0 D), and severe (K = 52.0 D or higher). The following parameters were obtained: thinnest corneal thickness (TCT), anterior chamber depth (ACD), corneal volume (CV), anterior chamber angle (ACA), and anterior chamber volume (ACV).

RESULTS

One hundred twenty-nine eyes had mild keratoconus, 59 had moderate keratoconus, and 35 had severe keratoconus. There were no statistically significant differences between the keratoconus group and control group in age, sex, or eye distribution (P>.05). With the progression of the disease, TCT and ACD were statistically different between all groups (P<.05). There were statistically significant differences in ACA and CV measurements between the mild keratoconus and severe keratoconus groups (P<.05). Also, CV readings were significantly different between the control group and all keratoconus groups (P<.05), although there was no significant difference in ACA measurements (P>.05). Despite a progressive increase in the ACV with disease progression, the differences between groups were not statistically significant (P>.05) except between the severe keratoconus group and the control group (P<.05).

CONCLUSION

Anterior segment parameters of the eye showed significant alterations with the progression of keratoconus.

摘要

目的

使用旋转式Scheimpflug相机评估圆锥角膜进展过程中前房参数的变化。

设置

土耳其马拉蒂亚伊诺努大学图尔古特·奥扎尔医学中心眼科。

方法

使用Pentacam Scheimpflug相机(奥culus公司)对123例诊断为圆锥角膜患者的216只眼和112名正常受试者的224只眼进行评估。圆锥角膜眼根据平均角膜曲率计(K)读数分为3组:轻度(K<47.0屈光度[D])、中度(K = 47.0至52.0 D)和重度(K = 52.0 D或更高)。获得以下参数:最薄角膜厚度(TCT)、前房深度(ACD)、角膜体积(CV)、前房角(ACA)和前房容积(ACV)。

结果

129只眼为轻度圆锥角膜,59只眼为中度圆锥角膜,35只眼为重度圆锥角膜。圆锥角膜组与对照组在年龄、性别或眼别分布上无统计学显著差异(P>0.05)。随着疾病进展,所有组之间的TCT和ACD在统计学上存在差异(P<0.05)。轻度圆锥角膜组和重度圆锥角膜组之间的ACA和CV测量值存在统计学显著差异(P<0.05)。此外,对照组与所有圆锥角膜组之间的CV读数存在显著差异(P<0.05),尽管ACA测量值无显著差异(P>0.05)。尽管随着疾病进展ACV逐渐增加,但除重度圆锥角膜组与对照组之间(P<0.05)外,各组之间的差异无统计学意义(P>0.05)。

结论

随着圆锥角膜的进展,眼部前段参数显示出显著变化。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验