Lau Sze Lok, Chow Lop Keung, Leung Yiu Yan
*Consultant, Brånemark Osseointegration Centre, Hong Kong, China. †Clinical Assistant Professor, Discipline of Oral and Maxillofacial Surgery, The University of Hong Kong, Hong Kong, China.
Implant Dent. 2016 Oct;25(5):619-23. doi: 10.1097/ID.0000000000000437.
The objective of the study is to compare the accuracy of the measurement of gingival thickness using cone-beam computerized tomography (CBCT) with direct clinical measurement on a pig jaw model, aiming to provide an alternate and precise method to aid assessment of the gingival biotype before immediate implant placement at the esthetic zone.
Four pig mandibles were categorized separately into 14 different zones with each prominent tooth cusp as one. A high-resolution CBCT image was taken. Measurement of gingival thickness was performed using computer software and was compared with direct clinical measurements.
Intraclass correlation coefficient between clinical and CBCT measurements were 0.995 (pig 1), 0.945 (pig 2), 0.966 (pig 3), and 0.932 (pig 4), which indicated a good match between 2 measuring methods. Independent t test showed no significant difference between 2 independent investigators in all aspect of measurements (P > 0.05).
Measuring gingival thickness using CBCT is a predictable and accurate method to assess the gingival biotype of a patient, so as to predict the suitability of immediate implantation.
本研究的目的是在猪颌骨模型上比较使用锥形束计算机断层扫描(CBCT)测量牙龈厚度与直接临床测量的准确性,旨在提供一种替代且精确的方法,以辅助在美学区域即刻种植前评估牙龈生物型。
将四颗猪下颌骨分别分为14个不同区域,每个突出的牙尖为一个区域。拍摄高分辨率CBCT图像。使用计算机软件测量牙龈厚度,并与直接临床测量结果进行比较。
临床测量与CBCT测量之间的组内相关系数分别为0.995(猪1)、0.945(猪2)、0.966(猪3)和0.932(猪4),这表明两种测量方法之间匹配良好。独立t检验显示,两名独立研究者在所有测量方面均无显著差异(P>0.05)。
使用CBCT测量牙龈厚度是一种可预测且准确的方法,可用于评估患者的牙龈生物型,从而预测即刻种植的适用性。