Accuracy of methods to measure femoral head penetration within metal-backed acetabular components.

作者信息

Callary Stuart A, Solomon Lucian B, Holubowycz Oksana T, Campbell David G, Howie Donald W

机构信息

Discipline of Orthopaedics and Trauma, The University of Adelaide, Adelaide, South Australia, Australia.

Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Level 4 Bice Building, North Terrace, Adelaide, South Australia, 5000, Australia.

出版信息

J Orthop Res. 2017 May;35(5):988-996. doi: 10.1002/jor.23356. Epub 2016 Jul 12.

Abstract

A number of different software programs are used to investigate the in vivo wear of polyethylene bearings in total hip arthroplasty. With wear rates below 0.1 mm/year now commonly being reported for highly cross-linked polyethylene (XLPE) components, it is important to identify the accuracy of the methods used to measure such small movements. The aims of this study were to compare the accuracy of current software programs used to measure two-dimensional (2D) femoral head penetration (FHP) and to determine whether the accuracy is influenced by larger femoral heads or by different methods of representing the acetabular component within radiostereometric analysis (RSA). A hip phantom was used to compare known movements of the femoral head within a metal-backed acetabular component to FHP measured radiographically using RSA, Hip Analysis Suite (HAS), PolyWare, Ein Bild Roentgen Analyse (EBRA), and Roentgen Monographic Analysis Tool (ROMAN). RSA was significantly more accurate than the HAS, PolyWare, and ROMAN methods when measuring 2D FHP with a 28 mm femoral head. Femoral head size influenced the accuracy of HAS and ROMAN 2D FHP measurements, EBRA proximal measurements, and RSA measurements in the proximal and anterior direction. The use of different acetabular reference segments did not influence accuracy of RSA measurements. The superior accuracy and reduced variability of RSA wear measurements allow much smaller cohorts to be used in RSA clinical wear studies than those utilizing other software programs. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:988-996, 2017.

摘要

有许多不同的软件程序用于研究全髋关节置换术中聚乙烯髋臼杯的体内磨损情况。目前普遍报道,高度交联聚乙烯(XLPE)部件的磨损率低于0.1毫米/年,因此识别用于测量如此微小运动的方法的准确性很重要。本研究的目的是比较当前用于测量二维(2D)股骨头穿透(FHP)的软件程序的准确性,并确定准确性是否受较大股骨头或放射立体测量分析(RSA)中髋臼部件不同表示方法的影响。使用髋关节模型将金属背衬髋臼部件内已知的股骨头运动与使用RSA、髋关节分析套件(HAS)、PolyWare、X光片分析(EBRA)和X光片专题分析工具(ROMAN)通过X线摄影测量的FHP进行比较。在测量28毫米股骨头的二维FHP时,RSA比HAS、PolyWare和ROMAN方法显著更准确。股骨头大小影响HAS和ROMAN二维FHP测量、EBRA近端测量以及RSA在近端和前方方向测量的准确性。使用不同的髋臼参考节段不影响RSA测量的准确性。与使用其他软件程序相比,RSA磨损测量的更高准确性和更低变异性使得在RSA临床磨损研究中可以使用更小的队列。©2016骨科研究协会。由Wiley期刊公司出版。《骨科研究杂志》35:988 - 996,2017年。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验