Suppr超能文献

通过23G经结膜无缝合玻璃体切割系统被动取出硅油。

Passive removal of silicone oil through 23 gauge transconjunctival sutureless vitrectomy system.

作者信息

Siyal Nisar Ahmed, Hargun Lakhani Das, Wahab Shahid

机构信息

Nisar Ahmed Siyal, Assistant Professor, Ophthalmology Unit I, Dow University of Health Sciences & Civil Hospital, Karachi, Pakistan.

Lakhani Das Hargun, Assistant Professor, Ophthalmology Unit I, Dow University of Health Sciences & Civil Hospital, Karachi, Pakistan.

出版信息

Pak J Med Sci. 2016 May-Jun;32(3):652-6. doi: 10.12669/pjms.323.9498.

Abstract

OBJECTIVE

To study the outcomes of passive removal of silicone oil by 23 Gauge Transconjunctival Sutureless Vitrectomy System.

METHODS

This prospective, consecutive case series study was conducted at Ophthalmology Department Unit I, Dow University of Health Sciences, Civil Hospital Karachi from January 2011 to December 2014. Only psuedophakic eyes with silicone oil temponade were selected. Main outcome measures were intra ocular pressure, time taken for removal of silicone oil, per operative and post operative complications. Pre and post operative IOP was compared by using two-tailed paired t-test and mean values with standard deviation were computed using difference of 95% confidence interval. Chi square test was applied for correlation of different variables. P-value of less than 0.05 was considered statistically significant.

RESULTS

Out of 79 patients who underwent passive ROSO, 38 (48.1%) were males. Mean age of patients was 47.5±7.1 (sd) years. Mean time taken for passive ROSO was 7.31±2.41 (sd) minutes. Pre and post operative intra ocular pressure shows statistically significant (p=0.000) decrease in IOP. Retinal redetachment found in 13 (16.5%) cases during follow up period.

CONCLUSION

Passive removal of silicone oil with 23 G suture less vitrectomy system is safe and effective in terms of less per operative and post operative complications. In this simple technique, there is less tissue trauma and little time consumed so it provides more comfort to patients and surgeons as well.

摘要

目的

研究使用23G经结膜无缝线玻璃体切割系统被动取出硅油的效果。

方法

本前瞻性、连续病例系列研究于2011年1月至2014年12月在卡拉奇市立医院道健康科学大学眼科第一单元进行。仅选择硅油填充的人工晶状体眼。主要观察指标为眼压、硅油取出时间、术中及术后并发症。术前和术后眼压采用双尾配对t检验进行比较,并使用95%置信区间的差值计算均值及标准差。应用卡方检验分析不同变量的相关性。P值小于0.05被认为具有统计学意义。

结果

在79例行被动硅油取出术的患者中,38例(48.1%)为男性。患者平均年龄为47.5±7.1(标准差)岁。被动硅油取出术的平均时间为7.31±2.41(标准差)分钟。术前和术后眼压显示眼压有统计学意义的下降(p = 0.000)。随访期间13例(16.5%)患者出现视网膜再脱离。

结论

使用23G无缝线玻璃体切割系统被动取出硅油在减少术中及术后并发症方面是安全有效的。在这种简单的技术中,组织创伤小,耗时少,因此也为患者和外科医生提供了更多便利。

相似文献

5
Passive silicone oil removal in 23-gauge transconjunctival vitrectomy.23G经结膜玻璃体切除术中的被动硅油取出术
Ophthalmic Surg Lasers Imaging. 2011 Nov-Dec;42(6):514-5. doi: 10.3928/15428877-20111017-01.

本文引用的文献

2
Re-retinal detachment after silicone oil removal.硅油取出术后视网膜再脱离
Indian J Ophthalmol. 2012 Nov-Dec;60(6):501-2. doi: 10.4103/0301-4738.103769.
6
Active removal of silicone oil with 25-gauge sutureless system.
Retina. 2007 Oct;27(8):1133-5. doi: 10.1097/IAE.0b013e3181237cde.
9
Transconjunctival sutureless 23-gauge vitrectomy.经结膜无缝合23G玻璃体切除术
Retina. 2005 Feb-Mar;25(2):208-11. doi: 10.1097/00006982-200502000-00015.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验