• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

[Reliability of transcutaneous PO2 measurements and ear oximetry at different levels of exercise].

作者信息

Chailleux E, Caby I, Hervouet A, Ordronneau J, Chollet S

机构信息

Service de Pneumologie I, Hôpital G. & R. Laënnec, C.H.U. de Nantes.

出版信息

Rev Mal Respir. 1989;6(3):229-35.

PMID:2740587
Abstract

Measurement of transcutaneous PO2 (PtcO2) and of the saturation of hemoglobin by ear oximetry (StcO2) are two non-invasive methods which can be used when performing exercise tests in patients with respiratory failure. To evaluate their reliability, we have compared 18 patients recording the PtcO2 (Radiometer electrode TCM1) and of StcO2 (Biox II A) with arterial samples using a radial artery catheter at rest and at a level corresponding to 50% of the maximal predicted effort and at maximal power (Wmax) obtained at the time of a triangular exercise (increasing the charge at 15 watts/min). The PtcO2 was significantly lower than the PaO2 at rest and on exercise: the variation between PaO2 and PtcO2 was 1.85 kPa at rest (confidence interval -0.25 to 3.96 kPa) but decreased with exercise reaching 1.22 kPa at the last level of exercise (confidence interval -1.2 to 3.65 kPa). The relative raising of PtcO2 in relation to the PaO2 masks a fall in the observed PaO2 on average for the entire group (the PaO2 falls from 9.49 kPa to 8.62 kPa whereas the PtcO2 only falls from 7.64 kPa to 7.39 kPa). The mean StcO2 does not differ from th SaO2 at rest as on exercise. However, the confidence interval of the scatters between SaO2 and StcO2 increase considerably at maximal power: whereas it ranges between -5.5 and 3.5% at rest and in the middle range effort, and is between -13.4 and 11.1% at the last stage.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

相似文献

1
[Reliability of transcutaneous PO2 measurements and ear oximetry at different levels of exercise].
Rev Mal Respir. 1989;6(3):229-35.
2
[Reliability of the transcutaneous PO2 measurement in the adult by the TCM 1 radiometer electrode].
Bull Eur Physiopathol Respir. 1984 May-Jun;20(3):303-6.
3
[Invasive or transcutaneous measurements of oxygen saturation and blood gases? An evaluation of pulse oximetry and transcutaneous measurement of PO2 and PCO2 during rest and exercise].[氧饱和度和血气的侵入性或经皮测量?静息和运动期间脉搏血氧饱和度测定以及经皮测量PO2和PCO2的评估]
Tidsskr Nor Laegeforen. 1993 Mar 20;113(8):967-70.
4
Comparative accuracy of pulse oximetry and transcutaneous oxygen in assessing arterial saturation in pediatric intensive care.
Crit Care Med. 1990 Jul;18(7):725-7. doi: 10.1097/00003246-199007000-00009.
5
Evaluation of a new combined transcutaneous measurement of PCO2/pulse oximetry oxygen saturation ear sensor in newborn patients.新型经皮测量新生儿患者二氧化碳分压/脉搏血氧饱和度耳部传感器的评估。
Pediatrics. 2005 Jan;115(1):e64-8. doi: 10.1542/peds.2004-0946. Epub 2004 Dec 15.
6
[Fiberoptic measurement of arterial oxygen saturation in premature and term neonates].[早产儿和足月儿动脉血氧饱和度的光纤测量]
Z Geburtshilfe Neonatol. 1999 Mar-Apr;203(2):77-80.
7
[Comparison of arterial and transcutaneous oxygen partial pressure in infants with bronchopulmonary dysplasia].[支气管肺发育不良婴儿动脉血氧分压与经皮血氧分压的比较]
Arch Fr Pediatr. 1988 Oct;45(8):537-40.
8
Transcutaneous oxygen measurement during one-lung anaesthesia.单肺麻醉期间的经皮氧测量
Acta Anaesthesiol Scand. 1984 Jun;28(3):241-4. doi: 10.1111/j.1399-6576.1984.tb02051.x.
9
[Measurement of alveolar-arterial partial pressure of oxygen difference in patients with chronic obstructive pulmonary disease both at rest and during maximal exercise].[慢性阻塞性肺疾病患者静息和最大运动时肺泡-动脉血氧分压差的测量]
Zhonghua Yi Xue Za Zhi. 2007 Dec 4;87(45):3192-5.
10
Pulse oximetry versus transcutaneous pO2 in sick newborn infants.患病新生儿的脉搏血氧饱和度测定与经皮氧分压测定对比
Scand J Clin Lab Invest Suppl. 1987;188:19-25. doi: 10.3109/00365518709168166.