Suppr超能文献

用于定量解析含环丙沙星和奥硝唑的两组分混合物的超高效液相色谱 - 光电二极管阵列数据集的双向和三向方法。

Two-way and three-way approaches to ultra high performance liquid chromatography-photodiode array dataset for the quantitative resolution of a two-component mixture containing ciprofloxacin and ornidazole.

作者信息

Dinç Erdal, Ertekin Zehra Ceren, Büker Eda

机构信息

Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey.

出版信息

J Sep Sci. 2016 Sep;39(18):3488-97. doi: 10.1002/jssc.201600382.

Abstract

Two-way and three-way calibration models were applied to ultra high performance liquid chromatography with photodiode array data with coeluted peaks in the same wavelength and time regions for the simultaneous quantitation of ciprofloxacin and ornidazole in tablets. The chromatographic data cube (tensor) was obtained by recording chromatographic spectra of the standard and sample solutions containing ciprofloxacin and ornidazole with sulfadiazine as an internal standard as a function of time and wavelength. Parallel factor analysis and trilinear partial least squares were used as three-way calibrations for the decomposition of the tensor, whereas three-way unfolded partial least squares was applied as a two-way calibration to the unfolded dataset obtained from the data array of ultra high performance liquid chromatography with photodiode array detection. The validity and ability of two-way and three-way analysis methods were tested by analyzing validation samples: synthetic mixture, interday and intraday samples, and standard addition samples. Results obtained from two-way and three-way calibrations were compared to those provided by traditional ultra high performance liquid chromatography. The proposed methods, parallel factor analysis, trilinear partial least squares, unfolded partial least squares, and traditional ultra high performance liquid chromatography were successfully applied to the quantitative estimation of the solid dosage form containing ciprofloxacin and ornidazole.

摘要

将双向和三向校准模型应用于具有光电二极管阵列数据的超高效液相色谱,该数据在相同波长和时间区域存在共洗脱峰,用于同时定量片剂中的环丙沙星和奥硝唑。通过记录含有环丙沙星、奥硝唑以及作为内标的磺胺嘧啶的标准溶液和样品溶液的色谱光谱随时间和波长的变化,获得色谱数据立方体(张量)。平行因子分析和三线性偏最小二乘法用作张量分解的三向校准,而三向展开偏最小二乘法作为双向校准应用于从具有光电二极管阵列检测的超高效液相色谱数据阵列获得的展开数据集。通过分析验证样品(合成混合物、日间和日内样品以及标准加入样品)来测试双向和三向分析方法的有效性和能力。将双向和三向校准得到的结果与传统超高效液相色谱提供的结果进行比较。所提出的方法,即平行因子分析、三线性偏最小二乘法、展开偏最小二乘法以及传统超高效液相色谱,成功应用于含有环丙沙星和奥硝唑的固体剂型的定量评估。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验