Suppr超能文献

在共定位光学相干断层扫描引导下,使用角分辨低相干干涉测量法分析组织中的空间相关性。

Analyzing spatial correlations in tissue using angle-resolved low coherence interferometry measurements guided by co-located optical coherence tomography.

作者信息

Kim Sanghoon, Heflin Stephanie, Kresty Laura A, Halling Meredith, Perez Laura N, Ho Derek, Crose Michael, Brown William, Farsiu Sina, Arshavsky Vadim, Wax Adam

机构信息

Department of Biomedical Engineering, Duke University, Durham, NC 27708, USA.

Department of Ophthalmology, Duke University, Durham, NC 27708, USA.

出版信息

Biomed Opt Express. 2016 Mar 21;7(4):1400-14. doi: 10.1364/BOE.7.001400. eCollection 2016 Apr 1.

Abstract

Angle-resolved low coherence interferometry (a/LCI) is an optical technique used to measure nuclear morphology in situ. However, a/LCI is not an imaging modality and can produce ambiguous results when the measurements are not properly oriented to the tissue architecture. Here we present a 2D a/LCI system which incorporates optical coherence tomography imaging to guide the measurements. System design and characterization are presented, along with example cases which demonstrate the utility of the combined measurements. In addition, future development and applications of this dual modality approach are discussed.

摘要

角分辨低相干干涉测量法(a/LCI)是一种用于原位测量细胞核形态的光学技术。然而,a/LCI并非一种成像方式,当测量未正确针对组织结构时,可能会产生模糊的结果。在此,我们展示了一种二维a/LCI系统,该系统结合了光学相干断层扫描成像以指导测量。文中介绍了系统设计与特性,以及展示联合测量效用的示例案例。此外,还讨论了这种双模态方法的未来发展与应用。

相似文献

3
In situ detection of nuclear atypia in Barrett's esophagus by using angle-resolved low-coherence interferometry.
Gastrointest Endosc. 2007 Mar;65(3):487-91. doi: 10.1016/j.gie.2006.10.016.
4
A scattering phantom for observing long range order with two-dimensional angle-resolved Low-Coherence Interferometry.
Biomed Opt Express. 2013 Aug 26;4(9):1742-8. doi: 10.1364/BOE.4.001742. eCollection 2013.
5
Spatial scanning of a sample with two-dimensional angle-resolved low-coherence interferometry for analysis of anisotropic scatterers.
Biomed Opt Express. 2020 Jul 20;11(8):4419-4430. doi: 10.1364/BOE.398052. eCollection 2020 Aug 1.
6
Scanning system for angle-resolved low-coherence interferometry.
Opt Lett. 2017 Nov 15;42(22):4581-4584. doi: 10.1364/OL.42.004581.
8
Angular range, sampling and noise considerations for inverse light scattering analysis of nuclear morphology.
J Biophotonics. 2019 Feb;12(2):e201800258. doi: 10.1002/jbio.201800258. Epub 2018 Oct 12.
10
Label-free, high-throughput measurements of dynamic changes in cell nuclei using angle-resolved low coherence interferometry.
Biophys J. 2008 Jun;94(12):4948-56. doi: 10.1529/biophysj.107.124107. Epub 2008 Mar 7.

引用本文的文献

1
Recovery of angular scattering profiles through a flexible multimode fiber.
Opt Express. 2024 Jun 3;32(12):21092-21101. doi: 10.1364/OE.522905.
3
Light scattering methods for tissue diagnosis.
Optica. 2019 Apr 20;6(4):479-489. doi: 10.1364/optica.6.000479.
4
Spatial scanning of a sample with two-dimensional angle-resolved low-coherence interferometry for analysis of anisotropic scatterers.
Biomed Opt Express. 2020 Jul 20;11(8):4419-4430. doi: 10.1364/BOE.398052. eCollection 2020 Aug 1.
5
Scattering Angle Resolved Optical Coherence Tomography Detects Early Changes in 3xTg Alzheimer's Disease Mouse Model.
Transl Vis Sci Technol. 2020 Apr 24;9(5):18. doi: 10.1167/tvst.9.5.18. eCollection 2020 Apr.
6
Multimodal Coherent Imaging of Retinal Biomarkers of Alzheimer's Disease in a Mouse Model.
Sci Rep. 2020 May 13;10(1):7912. doi: 10.1038/s41598-020-64827-2.
9
Dual-axis optical coherence tomography for deep tissue imaging.
Opt Lett. 2017 Jun 15;42(12):2302-2305. doi: 10.1364/OL.42.002302.

本文引用的文献

1
Evaluation of hybrid algorithm for analysis of scattered light using ex vivo nuclear morphology measurements of cervical epithelium.
Biomed Opt Express. 2015 Jul 7;6(8):2755-65. doi: 10.1364/BOE.6.002755. eCollection 2015 Aug 1.
2
Dual-modality fiber-based OCT-TPL imaging system for simultaneous microstructural and molecular analysis of atherosclerotic plaques.
Biomed Opt Express. 2015 Apr 10;6(5):1665-78. doi: 10.1364/BOE.6.001665. eCollection 2015 May 1.
3
Co-localized confocal Raman spectroscopy and optical coherence tomography (CRS-OCT) for depth-resolved analyte detection in tissue.
Biomed Opt Express. 2015 May 8;6(6):2022-35. doi: 10.1364/BOE.6.002022. eCollection 2015 Jun 1.
4
Interferometric synthetic aperture microscopy.
Nat Phys. 2007 Feb 1;3(2):129-134. doi: 10.1038/nphys514.
5
Modeling Light Scattering in Tissue as Continuous Random Media Using a Versatile Refractive Index Correlation Function.
IEEE J Sel Top Quantum Electron. 2013 Sep 6;20(2):7000514. doi: 10.1109/JSTQE.2013.2280999.
6
Inverse scattering solutions using low-coherence light.
Opt Lett. 2014 Aug 1;39(15):4494-7. doi: 10.1364/OL.39.004494.
7
Automatic segmentation of up to ten layer boundaries in SD-OCT images of the mouse retina with and without missing layers due to pathology.
Biomed Opt Express. 2014 Jan 7;5(2):348-65. doi: 10.1364/BOE.5.000348. eCollection 2014 Feb 1.
9
A scattering phantom for observing long range order with two-dimensional angle-resolved Low-Coherence Interferometry.
Biomed Opt Express. 2013 Aug 26;4(9):1742-8. doi: 10.1364/BOE.4.001742. eCollection 2013.
10
Can OCT be sensitive to nanoscale structural alterations in biological tissue?
Opt Express. 2013 Apr 8;21(7):9043-59. doi: 10.1364/OE.21.009043.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验