Suppr超能文献

一种用于检测抗b型流感嗜血杆菌抗体的高通量血清杀菌试验。

A high throughput serum bactericidal assay for antibodies to Haemophilus influenzae type b.

作者信息

Kim Han Wool, Kim Kyung-Hyo, Kim JiHye, Nahm Moon H

机构信息

Center for Vaccine Evaluation and Study, Medical Research Institute, School of Medicine, Ewha Womans University, Seoul, Republic of Korea.

Department of Pediatrics, School of Medicine, Ewha Womans University, Seoul, Republic of Korea.

出版信息

BMC Infect Dis. 2016 Sep 5;16(1):473. doi: 10.1186/s12879-016-1808-4.

Abstract

BACKGROUND

The protective capacities of antibodies induced with Haemophilus influenzae type b (Hib) vaccines can be directly assessed in vitro with a Hib-specific serum bactericidal assay (SBA). However, the conventional SBA requires several tedious steps including manual counting of bacterial colonies, and therefore, it is seldom used.

METHODS

To overcome these limitations, we have improved the conventional SBA by using frozen target bacteria and by developing an automated colony counting method based on agar plates with the chromogenic dye 2, 3, 5-triphenyl tetrazolium chloride (TTC).

RESULTS

These changes enabled us to analyze about 100 serum samples per day per person by SBA. When the intra- and inter-assay precisions were studied, this assay showed a coefficient of variation (CV) ranging from 1 to 38 %. To monitor the long term assay stability for assays involving different bacteria lots, complement lots, and operators, we analyzed bactericidal indices of quality control samples obtained over a 6 year period and found the CV to be about 35-50 %. Lastly, our SBA results were compared with the ELISA results obtained using 90 serum samples from children. We showed that the bactericidal index correlated with IgG anti-Hib antibody levels (r = 0.84), with a bactericidal index of 10 corresponding approximately to 0.15 μg/mL IgG, the widely accepted protective level of antibody.

CONCLUSION

We describe a simple high throughput SBA for anti-Hib antibodies that would be useful for evaluating various Hib vaccines. While additional work will be needed to standardize the assay, this SBA should greatly facilitate studies of Hib vaccines.

摘要

背景

用b型流感嗜血杆菌(Hib)疫苗诱导产生的抗体的保护能力可通过Hib特异性血清杀菌试验(SBA)在体外直接评估。然而,传统的SBA需要几个繁琐的步骤,包括人工计数细菌菌落,因此很少使用。

方法

为克服这些局限性,我们通过使用冷冻靶细菌以及开发基于含有显色染料2,3,5-三苯基氯化四氮唑(TTC)的琼脂平板的自动菌落计数方法,对传统SBA进行了改进。

结果

这些改变使我们能够每人每天通过SBA分析约100份血清样本。在研究批内和批间精密度时,该试验的变异系数(CV)为1%至38%。为监测涉及不同细菌批次、补体批次和操作人员的试验的长期稳定性,我们分析了6年期间获得的质量控制样本的杀菌指数,发现CV约为35%至50%。最后,我们将SBA结果与使用90份儿童血清样本获得的ELISA结果进行了比较。我们发现杀菌指数与IgG抗Hib抗体水平相关(r = 0.84),杀菌指数为10时大约对应于0.15μg/mL IgG,这是广泛接受的抗体保护水平。

结论

我们描述了一种用于抗Hib抗体的简单高通量SBA,这将有助于评估各种Hib疫苗。虽然需要额外的工作来规范该试验,但这种SBA应能极大地促进Hib疫苗的研究。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/73d4/5011942/6b753bd72bea/12879_2016_1808_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验