Suppr超能文献

4岁儿童手腕和髋部佩戴式活动记录仪加速度计的校准与验证

Calibration and Validation of a Wrist- and Hip-Worn Actigraph Accelerometer in 4-Year-Old Children.

作者信息

Johansson Elin, Larisch Lisa-Marie, Marcus Claude, Hagströmer Maria

机构信息

Department of Neurobiology, Care Sciences and Society, Karolinska Institutet, Stockholm, Sweden.

Department of Clinical Science, Technology and Intervention, Karolinska Institutet, Stockholm, Sweden.

出版信息

PLoS One. 2016 Sep 12;11(9):e0162436. doi: 10.1371/journal.pone.0162436. eCollection 2016.

Abstract

INTRODUCTION

To determine time spent at different physical activity intensities, accelerometers need calibration. The aim of this study was to develop and cross-validate intensity thresholds for the Actigraph GT3X+ accelerometer for wrist and hip placement in four-year-old children.

METHODS

In total 30 children (49 months, SD 3.7) were recruited from five preschools in Stockholm. Equipped with an accelerometer on the wrist and another on the hip, children performed three indoor activities and one free-play session while being video recorded. Subsequently, physical activity intensity levels were coded every 5th second according to the Children's Activity Rating Scale. Receiver Operating Characteristic (ROC) curves was used to develop wrist and hip intensity thresholds, the upper threshold for sedentary, and lower threshold for moderate-to-vigorous physical activity (MVPA), for the vertical axis (VA) and for the vector magnitude (VM). A leave-one-out method was used to cross-validate the thresholds.

RESULTS

Intensity thresholds for wrist placement were ≤ 178 (VA) and ≤ 328 (VM) for sedentary and ≥ 871 (VA) and ≥ 1393 (VM) counts/5 seconds for MVPA. The corresponding thresholds for hip placement were ≤ 43 (VA) and ≤ 105 (VM) for sedentary and ≥ 290 (VA) and ≥ 512 (VM) for MVPA. The quadratic weighted Kappa was 0.92 (95% CI 0.91-0.93) (VA) and 0.95 (95% CI 0.94-0.96) (VM) for the wrist-worn accelerometer and 0.76 (98% CI 0.74-0.77) and 0.86 (95% CI 0.85-0.87) for the hip-worn.

CONCLUSION

Using wrist placement and the VM when measuring physical activity with accelerometry in 4-year-old children is recommended.

摘要

引言

为了确定在不同身体活动强度下所花费的时间,加速度计需要进行校准。本研究的目的是为Actigraph GT3X+加速度计开发并交叉验证用于4岁儿童手腕和髋部佩戴的强度阈值。

方法

从斯德哥尔摩的五所幼儿园共招募了30名儿童(49个月,标准差3.7)。儿童手腕和髋部分别佩戴一个加速度计,进行三项室内活动和一次自由玩耍活动,同时进行视频记录。随后,根据儿童活动评分量表,每隔5秒对身体活动强度水平进行编码。使用受试者工作特征(ROC)曲线来确定手腕和髋部的强度阈值,即久坐的上限阈值和中度至剧烈身体活动(MVPA)的下限阈值,分别针对垂直轴(VA)和矢量大小(VM)。采用留一法对阈值进行交叉验证。

结果

手腕佩戴时,久坐的强度阈值为垂直轴(VA)≤178、矢量大小(VM)≤328,中度至剧烈身体活动(MVPA)为垂直轴(VA)≥871、矢量大小(VM)≥1393计数/5秒。髋部佩戴时,久坐的相应阈值为垂直轴(VA)≤43、矢量大小(VM)≤105,中度至剧烈身体活动(MVPA)为垂直轴(VA)≥290、矢量大小(VM)≥512。手腕佩戴的加速度计,二次加权卡帕系数在垂直轴(VA)为0.92(95%置信区间0.91 - 0.93)、矢量大小(VM)为0.95(95%置信区间0.94 - 0.96);髋部佩戴的加速度计,二次加权卡帕系数在垂直轴(VA)为0.76(98%置信区间0.74 - 0.77)、矢量大小(VM)为0.86(95%置信区间0.85 - 0.87)。

结论

建议在4岁儿童中使用加速度计测量身体活动时采用手腕佩戴方式并使用矢量大小(VM)。

相似文献

引用本文的文献

本文引用的文献

8
Calibration and validation of the ActiGraph GT3X+ in 2-3 year olds.ActiGraph GT3X+ 在2至3岁儿童中的校准与验证
J Sci Med Sport. 2014 Nov;17(6):617-22. doi: 10.1016/j.jsams.2013.11.005. Epub 2013 Nov 28.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验