Abstract

Background and Purpose. Contrast media (CM) for magnetic resonance imaging (MRI) may determine the development of acute adverse reactions. Objective was to retrospectively assess the frequency and severity of adverse reactions associated with gadolinium-based contrast agents (GBCAs) injection in patients who underwent MRI. Material and Methods. At our center 10608 MRI examinations with CM were performed using five different GBCAs: Gd-BOPTA (MultiHance), Gd-DTPA (Magnevist), Gd-EOBDTPA (Primovist), Gd-DOTA (Dotarem), and Gd-BTDO3A (Gadovist). Results. 32 acute adverse reactions occurred, accounting for 0.3% of all administration. Twelve reactions were associated with Gd-DOTA injection (0.11%), 9 with Gd-BOPTA injection (0.08%), 6 with Gd-BTDO3A (0.056%), 3 with Gd-EOB-DTPA (0.028%), and 2 with Gd-DTPA (0.018%). Twenty-four reactions (75.0%) were mild, four (12.5%) moderate, and four (12.5%) severe. The most severe reactions were seen associated with use of Gd-BOPTA, with 3 severe reactions in 32 total reactions. Conclusion. Acute adverse reactions are generally rare with the overall adverse reaction rate of 0.3%. The most common adverse reactions were not severe, consisting in skin rash and hives.

摘要

背景与目的。磁共振成像(MRI)造影剂(CM)可能会引发急性不良反应。目的是回顾性评估接受MRI检查的患者注射钆基造影剂(GBCA)后不良反应的发生率和严重程度。材料与方法。在我们中心,使用五种不同的GBCA进行了10608次使用CM的MRI检查:钆贝葡胺(MultiHance)、钆喷酸葡胺(马根维显)、钆塞酸二钠(普美显)、钆特酸(Dotarem)和钆布醇(Gadovist)。结果。发生了32例急性不良反应,占所有给药病例的0.3%。12例反应与钆特酸注射有关(0.11%),9例与钆贝葡胺注射有关(0.08%),6例与钆布醇有关(0.056%),3例与钆塞酸二钠有关(0.028%),2例与钆喷酸葡胺有关(0.018%)。24例反应(75.0%)为轻度,4例(12.5%)为中度,4例(12.5%)为重度。最严重的反应与钆贝葡胺的使用有关,在32例总反应中有3例严重反应。结论。急性不良反应通常很少见,总体不良反应率为0.3%。最常见的不良反应不严重,表现为皮疹和荨麻疹。

相似文献

1
Immediate Adverse Reactions to Gadolinium-Based MR Contrast Media: A Retrospective Analysis on 10,608 Examinations.
Biomed Res Int. 2016;2016:3918292. doi: 10.1155/2016/3918292. Epub 2016 Aug 29.
4
Liver vessel enhancement by Gd-BOPTA and Gd-EOB-DTPA: a comparison in healthy volunteers.
Acta Radiol. 2009 Sep;50(7):709-15. doi: 10.1080/02841850903055603.
5
Incidence and severity of acute adverse reactions to four different gadolinium-based MR contrast agents.
Magn Reson Med Sci. 2014;13(1):1-6. doi: 10.2463/mrms.2012-0051. Epub 2014 Jan 31.
6
Gadolinium released by the linear gadolinium-based contrast-agent Gd-DTPA decreases the activity of human epithelial Na channels (ENaCs).
Biochim Biophys Acta Biomembr. 2017 May;1859(5):1040-1048. doi: 10.1016/j.bbamem.2017.02.019. Epub 2017 Feb 28.
8
Pharmacokinetics and imaging properties of Gd-EOB-DTPA in patients with hepatic and renal impairment.
Invest Radiol. 2011 Sep;46(9):556-66. doi: 10.1097/RLI.0b013e31821a218a.
9
Risk of acute kidney injury after exposure to gadolinium-based contrast in patients with renal impairment.
Ren Fail. 2011;33(8):758-64. doi: 10.3109/0886022X.2011.599911. Epub 2011 Jul 22.
10
Adverse reactions to gadolinium contrast media: a review of 36 cases.
AJR Am J Roentgenol. 1996 Oct;167(4):847-9. doi: 10.2214/ajr.167.4.8819369.

引用本文的文献

1
Gadolinium toxicity: mechanisms, clinical manifestations, and nanoparticle role.
Arch Toxicol. 2025 Jul 3. doi: 10.1007/s00204-025-04124-x.
2
Contrast Agents in Breast MRI: State of the Art and Future Perspectives.
Biomedicines. 2025 Mar 31;13(4):829. doi: 10.3390/biomedicines13040829.
3
A modified non-contrast MRI in the preoperative examination of periacetabular osteotomy at 3.0T.
J Orthop Surg Res. 2025 Jan 31;20(1):121. doi: 10.1186/s13018-025-05521-9.
4
Feasibility of relaxation along a fictitious field in the 2nd rotating frame (T) mapping in the human myocardium at 3 T.
Front Cardiovasc Med. 2024 Dec 4;11:1373240. doi: 10.3389/fcvm.2024.1373240. eCollection 2024.
5
Acute adverse reactions after multiple initially well-tolerated gadolinium-based contrast-enhanced abdomen MRIs in pediatric patients.
PLoS One. 2024 Dec 3;19(12):e0313495. doi: 10.1371/journal.pone.0313495. eCollection 2024.
8
Identification of peroneal artery perforators using non-contrast-enhanced T2prep multi-shot gradient echo planar imaging MRA.
Radiol Phys Technol. 2024 Sep;17(3):610-619. doi: 10.1007/s12194-024-00799-6. Epub 2024 May 28.

本文引用的文献

1
Gadolinium-based contrast agent toxicity: a review of known and proposed mechanisms.
Biometals. 2016 Jun;29(3):365-76. doi: 10.1007/s10534-016-9931-7. Epub 2016 Apr 6.
4
Adverse allergic reactions to linear ionic gadolinium-based contrast agents: experience with 194, 400 injections.
Clin Radiol. 2015 May;70(5):466-75. doi: 10.1016/j.crad.2014.12.011. Epub 2015 Jan 24.
5
Risk management in magnetic resonance: failure mode, effects, and criticality analysis.
Biomed Res Int. 2013;2013:763186. doi: 10.1155/2013/763186. Epub 2013 Sep 19.
6
Risk factors for adverse reactions from contrast agents for computed tomography.
BMC Med Inform Decis Mak. 2013 Jan 30;13:18. doi: 10.1186/1472-6947-13-18.
7
Immediate hypersensitivity reaction to gadolinium-based MR contrast media.
Radiology. 2012 Aug;264(2):414-22. doi: 10.1148/radiol.12112025. Epub 2012 May 1.
8
Incidence of immediate gadolinium contrast media reactions.
AJR Am J Roentgenol. 2011 Feb;196(2):W138-43. doi: 10.2214/AJR.10.4885.
10
Extracellular gadolinium contrast agents: differences in stability.
Eur J Radiol. 2008 May;66(2):175-9. doi: 10.1016/j.ejrad.2008.01.025. Epub 2008 Mar 14.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验