Suppr超能文献

女性运动员负重背屈弓步试验(WBLT)中评估背屈的各种测量方法的评分者内信度及一致性。

Intra-rater reliability and agreement of various methods of measurement to assess dorsiflexion in the Weight Bearing Dorsiflexion Lunge Test (WBLT) among female athletes.

作者信息

Langarika-Rocafort Argia, Emparanza José Ignacio, Aramendi José F, Castellano Julen, Calleja-González Julio

机构信息

Department of Physical Education and Sport, Faculty of Physical Activity and Sport Sciences, University of the Basque Country (UPV/EHU), Portal de Lasarte, 71, 01007, Vitoria-Gasteiz, Spain; Faculty of Psychology and Education, University of Deusto, Paseo de las Universidades, 24, 48007, Bilbao, Spain.

Clinical Epidemiology Unit, CASPe, CIBER-ESP, BioDonostia, University Hospital Donostia, Paseo del Doctor Begiristain, 117, 20080, Donostia-San Sebastian, Spain.

出版信息

Phys Ther Sport. 2017 Jan;23:37-44. doi: 10.1016/j.ptsp.2016.06.010. Epub 2016 Jun 29.

Abstract

OBJECTIVES

To examine the intra-observer reliability and agreement between five methods of measurement for dorsiflexion during Weight Bearing Dorsiflexion Lunge Test and to assess the degree of agreement between three methods in female athletes.

DESIGN

Repeated measurements study design.

SETTING

Volleyball club.

PARTICIPANTS

Twenty-five volleyball players.

MAIN OUTCOME MEASUREMENTS

Dorsiflexion was evaluated using five methods: heel-wall distance, first toe-wall distance, inclinometer at tibia, inclinometer at Achilles tendon and the dorsiflexion angle obtained by a simple trigonometric function. For the statistical analysis, agreement was studied using the Bland-Altman method, the Standard Error of Measurement and the Minimum Detectable Change. Reliability analysis was performed using the Intraclass Correlation Coefficient.

RESULTS

Measurement methods using the inclinometer had more than 6° of measurement error. The angle calculated by trigonometric function had 3.28° error. The reliability of inclinometer based methods had ICC values < 0.90. Distance based methods and trigonometric angle measurement had an ICC values > 0.90. Concerning the agreement between methods, there was from 1.93° to 14.42° bias, and from 4.24° to 7.96° random error.

CONCLUSION

To assess DF angle in WBLT, the angle calculated by a trigonometric function is the most repeatable method. The methods of measurement cannot be used interchangeably.

摘要

目的

检验在负重背屈弓步试验中,五种背屈测量方法的观察者内信度及一致性,并评估女性运动员中三种方法之间的一致程度。

设计

重复测量研究设计。

地点

排球俱乐部。

参与者

25名排球运动员。

主要测量指标

使用五种方法评估背屈:足跟-墙壁距离、第一足趾-墙壁距离、胫骨处倾角计、跟腱处倾角计以及通过简单三角函数获得的背屈角度。对于统计分析,使用布兰德-奥特曼方法、测量标准误差和最小可检测变化来研究一致性。使用组内相关系数进行信度分析。

结果

使用倾角计的测量方法存在超过6°的测量误差。通过三角函数计算的角度有3.28°的误差。基于倾角计的方法的信度,其组内相关系数值<0.90。基于距离的方法和三角角度测量的组内相关系数值>0.90。关于方法之间的一致性,偏差为1.93°至14.42°,随机误差为4.24°至7.96°。

结论

为评估负重背屈弓步试验中的背屈角度,通过三角函数计算的角度是最可重复的方法。这些测量方法不能互换使用。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验