Miglio A, Stefanetti V, Antognoni M T, Cappelli K, Capomaccio S, Coletti M, Passamonti F
Department of Veterinary Medicine, University of Perugia, Perugia, Italy.
J Vet Intern Med. 2016 Nov;30(6):1830-1837. doi: 10.1111/jvim.14593. Epub 2016 Oct 13.
Bacterial contamination of whole blood (WB) units can result in transfusion-transmitted infection, but the extent of the risk has not been established and may be underestimated in veterinary medicine.
To detect, quantify, and identify bacterial microorganisms in 49 canine WB units during their shelf life.
Forty-nine healthy adult dogs.
Forty-nine WB units were included in the study. Immediately after collection, 8 sterile samples from the tube segment line of each unit were aseptically collected and tested for bacterial contamination on days 0, 1, 7, 14, 21, 28, 35, and 42 of storage. A qPCR assay was performed on days 0, 21, and 35 to identify and quantify any bacterial DNA.
On bacterial culture, 47/49 blood units were negative at all time points tested, 1 unit was positive for Enterococcus spp. on days 0 and 1, and 1 was positive for Escherichia coli on day 35. On qPCR assay, 26 of 49 blood units were positive on at least 1 time point and the bacterial loads of the sequences detected (Propionobacterium spp., Corynebacterium spp., Caulobacter spp., Pseudomonas spp., Enterococcus spp., Serratia spp., and Leucobacter spp.) were <80 genome equivalents (GE)/μL.
Most of the organisms detected were common bacteria, not usually implicated in septic transfusion reactions. The very low number of GE detected constitutes an acceptable risk of bacterial contamination, indicating that WB units have a good sanitary shelf life during commercial storage.
全血(WB)单位的细菌污染可导致输血传播感染,但风险程度尚未确定,在兽医学中可能被低估。
检测、量化和鉴定49个犬全血单位在其保存期内的细菌微生物。
49只健康成年犬。
49个全血单位纳入研究。采集后立即从每个单位的管段无菌采集8个样本,并在储存的第0、1、7、14、21、28、35和42天检测细菌污染情况。在第0、21和35天进行qPCR检测以鉴定和量化任何细菌DNA。
在细菌培养中,49个血液单位中的47个在所有测试时间点均为阴性,1个单位在第0天和第1天对肠球菌属呈阳性,1个在第35天对大肠杆菌呈阳性。在qPCR检测中,49个血液单位中的26个在至少1个时间点呈阳性,检测到的序列(丙酸杆菌属、棒状杆菌属、柄杆菌属、假单胞菌属、肠球菌属、沙雷氏菌属和无色杆菌属)的细菌载量<80基因组当量(GE)/μL。
检测到的大多数微生物是常见细菌,通常与败血症输血反应无关。检测到的极低数量的基因组当量构成了可接受的细菌污染风险,表明全血单位在商业储存期间具有良好的卫生保存期。