Reliability of gait analysis using wearable sensors in patients with knee osteoarthritis.

作者信息

Kobsar Dylan, Osis Sean T, Phinyomark Angkoon, Boyd Jeffrey E, Ferber Reed

机构信息

Faculty of Kinesiology, University of Calgary, Calgary, Alberta, Canada.

Faculty of Kinesiology, University of Calgary, Calgary, Alberta, Canada.

出版信息

J Biomech. 2016 Dec 8;49(16):3977-3982. doi: 10.1016/j.jbiomech.2016.11.047. Epub 2016 Nov 16.


DOI:10.1016/j.jbiomech.2016.11.047
PMID:27889189
Abstract

The aim of this study was to determine the test-retest reliability of linear acceleration waveforms collected at the low back, thigh, shank, and foot during walking, in a cohort of knee osteoarthritis patients, by applying two separate sensor attitude correction methods (static attitude correction and dynamic attitude correction). Linear acceleration data were collected on the subjects׳ most affected limb during treadmill walking on two separate days. Results reveal all attitude corrected acceleration waveforms displayed high repeatability, with coefficient of multiple determination values ranging from 0.82 to 0.99. Overall, mediolateral accelerations and the thigh sensor demonstrated the lowest reliabilities, but interaction effects revealed only mediolateral accelerations at the thigh and foot sensors were different than other axes and sensor locations. Both attitude correction methods led to improved reliability of linear acceleration waveforms. These findings suggest that while all sensor locations and axes display acceptable reliability in a clinical knee osteoarthritis population, the back and shank locations, and the vertical and anteroposterior acceleration directions, are most reliable.

摘要

相似文献

[1]
Reliability of gait analysis using wearable sensors in patients with knee osteoarthritis.

J Biomech. 2016-12-8

[2]
Wearable sensors to predict improvement following an exercise intervention in patients with knee osteoarthritis.

J Neuroeng Rehabil. 2017-9-12

[3]
Test-retest reliability and minimal clinical change determination for 3-dimensional tibial and femoral accelerations during treadmill walking in knee osteoarthritis patients.

Arch Phys Med Rehabil. 2008-4

[4]
The reliability of using accelerometer and gyroscope for gait event identification on persons with dropped foot.

Gait Posture. 2008-2

[5]
Biomechanical mechanisms of toe-out gait performance in people with and without knee osteoarthritis.

Clin Biomech (Bristol). 2014-1

[6]
Criterion Validity of Linear Accelerations Measured with Low-Sampling-Frequency Accelerometers during Overground Walking in Elderly Patients with Knee Osteoarthritis.

Sensors (Basel). 2022-7-15

[7]
Wearable Sensor Data to Track Subject-Specific Movement Patterns Related to Clinical Outcomes Using a Machine Learning Approach.

Sensors (Basel). 2018-8-27

[8]
Reliability and criterion-related validity with a smartphone used in timed-up-and-go test.

Biomed Eng Online. 2014-12-2

[9]
Estimation of stride length in level walking using an inertial measurement unit attached to the foot: a validation of the zero velocity assumption during stance.

J Biomech. 2011-5-23

[10]
Ipsilateral and contralateral foot pronation affect lower limb and trunk biomechanics of individuals with knee osteoarthritis during gait.

Clin Biomech (Bristol). 2016-5

引用本文的文献

[1]
Biomechanical changes in lower extremity in individuals with knee osteoarthritis in the past decade: A scoping review.

Heliyon. 2024-6-7

[2]
Reliability of Wearable Sensors for Assessing Gait and Chair Stand Function at Home in People With Knee Osteoarthritis.

Arthritis Care Res (Hoboken). 2023-9

[3]
Applied Assessment Method for Varus Thrust during Walking in Patients with Knee Osteoarthritis Using Acceleration Data Measured by an Inertial Measurement Unit.

Sensors (Basel). 2022-8-27

[4]
Between-Day Reliability of Commonly Used IMU Features during a Fatiguing Run and the Effect of Speed.

Sensors (Basel). 2022-5-29

[5]
Comprehensive validation of a wearable foot sensor system for estimating spatiotemporal gait parameters by simultaneous three-dimensional optical motion analysis.

BMC Sports Sci Med Rehabil. 2022-4-17

[6]
Quantification of Movement in Stroke Patients under Free Living Conditions Using Wearable Sensors: A Systematic Review.

Sensors (Basel). 2022-1-28

[7]
The application of artificial intelligence and custom algorithms with inertial wearable devices for gait analysis and detection of gait-altering pathologies in adults: A scoping review of literature.

Digit Health. 2022-1-27

[8]
Wearable Inertial Sensors for Gait Analysis in Adults with Osteoarthritis-A Scoping Review.

Sensors (Basel). 2020-12-13

[9]
Quantifying varus thrust in knee osteoarthritis using wearable inertial sensors: A proof of concept.

Clin Biomech (Bristol). 2020-12

[10]
Coordination Pattern of the Thigh, Pelvic, and Lumbar Movements during the Gait of Patients with Hip Osteoarthritis.

J Healthc Eng. 2020

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

推荐工具

医学文档翻译智能文献检索