在患有膝骨关节炎的老年患者进行地面行走时,低频采样率加速计测量的线性加速度的标准效度。

Criterion Validity of Linear Accelerations Measured with Low-Sampling-Frequency Accelerometers during Overground Walking in Elderly Patients with Knee Osteoarthritis.

机构信息

Interdisciplinary Orthopaedics, Aalborg University Hospital, 9000 Aalborg, Denmark.

Department of Materials and Production, Aalborg University, 9220 Aalborg East, Denmark.

出版信息

Sensors (Basel). 2022 Jul 15;22(14):5289. doi: 10.3390/s22145289.

Abstract

Sensors with a higher sampling rate produce higher-quality data. However, for more extended periods of data acquisition, as in the continuous monitoring of patients, the handling of the generated big data becomes increasingly complicated. This study aimed to determine the validity and reliability of low-sampling-frequency accelerometer (SENS) measurements in patients with knee osteoarthritis. Data were collected simultaneously using SENS and a previously validated sensor (Xsens) during two repetitions of overground walking. The processed acceleration signals were compared with respect to different coordinate axes to determine the test-retest reliability and the agreement between the two systems in the time and frequency domains. In total, 44 participants were included. With respect to different axes, the interclass correlation coefficient for the repeatability of SENS measurements was [0.93-0.96]. The concordance correlation coefficients for the two systems' agreement were [0.81-0.91] in the time domain and [0.43-0.99] in the frequency domain. The absolute biases estimated by the Bland-Altman method were [0.0005-0.008] in the time domain and [0-0.008] in the frequency domain. Low-sampling-frequency accelerometers can provide relatively valid data for measuring the gait accelerations in patients with knee osteoarthritis and can be used in the future for remote patient monitoring.

摘要

传感器的采样率越高,生成的数据质量就越高。然而,对于更长时间的数据采集,例如对患者的连续监测,生成的大数据的处理会变得越来越复杂。本研究旨在确定在膝骨关节炎患者中,低采样频率加速度计(SENS)测量的有效性和可靠性。在两次地面行走重复过程中,同时使用 SENS 和之前经过验证的传感器(Xsens)采集数据。比较处理后的加速度信号在不同坐标轴上,以确定时间和频率域中测试-重测可靠性以及两个系统之间的一致性。总共纳入了 44 名参与者。对于不同的坐标轴,SENS 测量重复性的组内相关系数为[0.93-0.96]。两个系统在时间域中的一致性的 concordance 相关系数为[0.81-0.91],在频率域中为[0.43-0.99]。Bland-Altman 方法估计的绝对偏差在时间域中为[0.0005-0.008],在频率域中为[0-0.008]。低采样频率加速度计可以为测量膝骨关节炎患者的步态加速度提供相对有效的数据,并且将来可以用于远程患者监测。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/9734/9322915/54e15a3e1b2b/sensors-22-05289-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验