The interpretation of cell transplantation experiments is often dependent on the presence of an exogenous label for the identification of implanted cells. The exogenous labels Hoechst 33342, 5-bromo-2'-deoxyuridine (BrdU), PKH26, and Qtracker were compared for their labeling efficiency, cellular effects, and reliability to identify a human neural stem cell (hNSC) line implanted intracerebrally into the rat brain. Hoechst 33342 (2 mg/ml) exhibited a delayed cytotoxicity that killed all cells within 7 days. This label was hence not progressed to in vivo studies. PKH26 (5 μM), Qtracker (15 nM), and BrdU (0.2 μM) labeled 100% of the cell population at day 1, although BrdU labeling declined by day 7. BrdU and Qtracker exerted effects on proliferation and differentiation. PKH26 reduced viability and proliferation at day 1, but this normalized by day 7. In an in vitro coculture assay, all labels transferred to unlabeled cells. After transplantation, the reliability of exogenous labels was assessed against the gold standard of a human-specific nuclear antigen (HNA) antibody. BrdU, PKH26, and Qtracker resulted in a very small proportion (<2%) of false positives, but a significant amount of false negatives (∼30%), with little change between 1 and 7 days. Exogenous labels can therefore be reliable to identify transplanted cells without exerting major cellular effects, but validation is required. The interpretation of cell transplantation experiments should be presented in the context of the label's limitations.
细胞移植实验的解读通常依赖于用于识别植入细胞的外源性标记物。对Hoechst 33342、5-溴-2'-脱氧尿苷(BrdU)、PKH26和Qtracker这几种外源性标记物的标记效率、细胞效应及可靠性进行了比较,以确定脑内植入大鼠脑内的人神经干细胞(hNSC)系。Hoechst 33342(2mg/ml)表现出延迟的细胞毒性,在7天内杀死所有细胞。因此,该标记物未进入体内研究阶段。PKH26(5μM)、Qtracker(15nM)和BrdU(0.2μM)在第1天标记了100%的细胞群体,尽管BrdU标记在第7天时下降。BrdU和Qtracker对增殖和分化有影响。PKH26在第1天降低了细胞活力和增殖,但到第7天时恢复正常。在体外共培养试验中,所有标记物都转移到了未标记的细胞上。移植后,根据人特异性核抗原(HNA)抗体这一金标准评估外源性标记物的可靠性。BrdU, PKH26和Qtracker产生的假阳性比例非常小(<2%),但假阴性数量显著(约30%),在1至7天之间变化不大。因此,外源性标记物在识别移植细胞时可以是可靠的,且不会产生重大细胞效应,但仍需要进行验证。细胞移植实验的解读应结合标记物的局限性来呈现。