蒸汽高压灭菌对用于粘结两件式氧化锆基台的树脂水门汀拉伸强度的影响。

Effect of Steam Autoclaving on the Tensile Strength of Resin Cements Used for Bonding Two-Piece Zirconia Abutments.

作者信息

Fadanelli Marcos Alexandre, Amaral Flávia Lucisano Botelho do, Basting Roberta Tarkany, Turssi Cecilia Pedroso, Sotto-Maior Bruno Salles, França Fabiana Mantovani Gomes

机构信息

São Leopoldo Mandic Institute and Dental Research Center, Campinas/SP, Brazil.

出版信息

J Oral Implantol. 2017 Apr;43(2):87-93. doi: 10.1563/aaid-joi-D-16-00018. Epub 2016 Dec 14.

Abstract

The purpose of this study was to evaluate the effects of steam autoclave sterilization on the tensile strength of two types of resin cements used to bond customized CAD/CAM zirconia abutments onto titanium bases. Forty sets of zirconia abutments cemented to screwed titanium bases of implants analogs were divided into 4 groups (n = 10). Two groups were treated with a conventional chemically activated resin cement (ML, Multilink Ivoclar Vivadent) and the other two groups with a self-adhesive dual resin cement (RelyX U200, 3M ESPE). One group from each cement was submitted to steam autoclaving. The autoclave sterilization cycle was performed after 72 hours of cementation for 15 minutes at 121°C and 2.1 Kgf/cm. The samples were subjected to tensile strength testing in a universal testing machine (200 Kgf, 0.5 mm/min), from which the means and standard deviations were obtained in Newtons. Results showed (via ANOVA and Tukey's test; α = 0.05) that in the absence of steam autoclaving, no difference was observed in tensile strength between the cements tested: ML: 344.87 (93.79) and U200: 280 (92.42) (P = .314). Steam autoclaving, however, significantly increased tensile strength for the ML: 465.42 (87.87) compared to U200: 289.10 (49.02) (P < .001). Despite the significant increase in the ML samples (P = .013), autoclaving did not affect the tensile strength of the U200 samples (P > 0.05). The authors concluded that steam autoclaving increases the mean tensile strength of the chemically activated cement compared to the dual-cure self-adhesive cement. The performance of both cements evaluated was similar if the sterilization step was disconsidered.

摘要

本研究的目的是评估蒸汽高压灭菌对两种用于将定制CAD/CAM氧化锆基台粘结到钛基台上的树脂水门汀拉伸强度的影响。将四十套粘结到种植体模拟物的螺纹钛基台上的氧化锆基台分为4组(n = 10)。两组用传统化学活化树脂水门汀(ML,义获嘉威兰德Multilink)处理,另外两组用自粘结双固化树脂水门汀(3M ESPE的RelyX U200)处理。每种水门汀的一组进行蒸汽高压灭菌。在粘结72小时后,在121°C和2.1千克力/平方厘米的条件下进行15分钟的高压灭菌循环。样品在万能试验机上进行拉伸强度测试(200千克力,0.5毫米/分钟),从中获得以牛顿为单位的平均值和标准差。结果显示(通过方差分析和Tukey检验;α = 0.05),在没有蒸汽高压灭菌的情况下,测试的水门汀之间的拉伸强度没有差异:ML:344.87(93.79)和U200:280(92.42)(P = 0.314)。然而,蒸汽高压灭菌显著提高了ML的拉伸强度:465.42(87.87),而U200为289.10(49.02)(P < 0.001)。尽管ML样品的拉伸强度显著增加(P = 0.013),但高压灭菌并未影响U200样品的拉伸强度(P > 0.05)。作者得出结论,与双固化自粘结水门汀相比,蒸汽高压灭菌提高了化学活化水门汀的平均拉伸强度。如果不考虑灭菌步骤,所评估的两种水门汀的性能相似。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验