Suppr超能文献

在健康白种人群中通过光学相干断层扫描对小梁-虹膜接触进行定量分析及其患病率研究

Quantification of trabecular-iris contact and its prevalence by optical coherence tomography in a healthy Caucasian population.

作者信息

Fernández-Vigo José Ignacio, De-Pablo-Gómez-De-Liaño Lucía, Fernández-Vigo Cristina, Sánchez-Guillén Inés, Santos-Bueso Enrique, Martínez-de-la-Casa José María, García-Feijóo Julián, Fernández-Vigo José Ángel

机构信息

Department of Ophthalmology, Hospital Universitario Clínico San Carlos, Instituto de Investigación Sanitaria San Carlos (IdISSC), Madrid - Spain.

Centro Internacional de Oftalmología Avanzada, Madrid - Spain.

出版信息

Eur J Ophthalmol. 2017 Jun 26;27(4):417-422. doi: 10.5301/ejo.5000919. Epub 2016 Dec 16.

Abstract

PURPOSE

To determine the prevalence of trabecular-iris contact (TIC) and quantify this contact in healthy Caucasian individuals using Fourier-domain optical coherence tomography (FD-OCT).

METHODS

For this cross-sectional study, 2,012 eyes of 1,006 healthy subjects were recruited among individuals undergoing a routine ophthalmologic checkup. In each participant, age, sex, intraocular pressure, and spherical refractive error were first recorded along with anterior chamber depth and volume, central corneal thickness measured with the Pentacam, and axial length with the IOLMaster. Anterior chamber angle variables and the presence of TIC in the horizontal quadrants were determined by anterior segment FD-OCT (RTVue 100®). When TIC was observed, TIC length (TICL) and its percentage in relation to the length of the trabecular meshwork (TICL percentage) were also measured.

RESULTS

Trabecular-iris contact in the horizontal quadrants was observed in 34 eyes of 25 patients, representing 1.6% of the total number of eyes examined. In this subgroup of individuals, mean age was 55.8 years, 84% were women, and spherical refractive error ranged from -0.25 to 8.25 D. Eyes with TIC showed an angle width of less than 23.2 degrees and axial length shorter than 23.7 mm. Mean TICL was 239 ± 79 μm (103-495 μm) and mean TICL percentage was 46.9% ± 13.9% (17.2%-76.3%).

CONCLUSIONS

The prevalence of TIC was low in this population. Fourier-domain optical coherence tomography emerged as useful to assess its prevalence and quantify the extent of TIC.

摘要

目的

利用傅里叶域光学相干断层扫描(FD - OCT)确定小梁 - 虹膜接触(TIC)的患病率,并对健康白种人个体的这种接触进行量化。

方法

在这项横断面研究中,从接受常规眼科检查的个体中招募了1006名健康受试者的2012只眼睛。在每位参与者中,首先记录年龄、性别、眼压和球镜屈光不正,以及前房深度和容积、用Pentacam测量的中央角膜厚度和用IOLMaster测量的眼轴长度。通过眼前段FD - OCT(RTVue 100®)确定前房角变量和水平象限中TIC的存在情况。当观察到TIC时,还测量TIC长度(TICL)及其相对于小梁网长度的百分比(TICL百分比)。

结果

在25名患者的34只眼中观察到水平象限的小梁 - 虹膜接触,占检查眼睛总数的1.6%。在这个亚组个体中,平均年龄为55.8岁,84%为女性,球镜屈光不正范围为 - 0.25至8.25 D。有TIC的眼睛显示房角宽度小于23.2度,眼轴长度短于23.7 mm。平均TICL为239±79μm(103 - 495μm),平均TICL百分比为46.9%±13.9%(17.2% - 76.3%)。

结论

该人群中TIC的患病率较低。傅里叶域光学相干断层扫描对于评估其患病率和量化TIC的程度很有用。