*OD, MSc †PhD Rotterdam Ophthalmic Institute, Rotterdam, the Netherlands (GL); Instituto Universitario de Investigación en Envejecimiento, Universidad de Murcia, Murcia, Spain (GL, NL-G); Departamento de Electromagnetismo y Electrónica, Universidad de Murcia, Murcia, Spain (FV-M); and Netherlands Institute for Neuroscience, Royal Netherlands Academy of Arts and Sciences, Amsterdam, the Netherlands (TJTPvdB).

出版信息

Optom Vis Sci. 2017 Apr;94(4):496-504. doi: 10.1097/OPX.0000000000001043.

Abstract

PURPOSE

Multifocal contact lenses have been growing in popularity as a modality to correct presbyopic eyes, although visual side effects such as disability glare have been reported. The objective of this study was to investigate the effect of multifocal contact lenses on disability glare by means of ocular straylight.

METHODS

A prospective randomized, comparative study was performed that included 16 subjects free of ocular pathology. Straylight was measured using a commercial straylight meter with the natural and dilated pupil. Participants were fitted with Proclear Multifocal (Distance/Near), ACUVUE Oasys for Presbyopia, and Air Optix Aqua Multifocal randomized to the left or right eye. Straylight measurements were repeated with the contact lens in situ after the pupil dilation. Results obtained with the dilated pupil without contact lens acted as a control.

RESULTS

Diameter of the natural and dilated pupil was 2.87 ± 0.40 mm and 7.45 ± 0.86 mm, respectively (P < .001). After pupil dilation, straylight increased from 0.92 ± 0.13 log(s) to 1.04 ± 0.11 log(s) (P < .001). Of the four studied lenses, a significant difference was only found between Air Optix and the control group (P = .006). The latter showed also slightly increased light scatter.

CONCLUSIONS

A difference in measured straylight was found between the studied multifocal lenses. The observed variability and the straylight-pupil size dependency should be taken into account to avoid elevated straylight in multifocal contact lens wearers. The reason for the observed differences in straylight must be the subject of future studies.

摘要

目的

多焦点隐形眼镜作为矫正老花眼的一种方式越来越受欢迎,尽管有报道称其存在如失能眩光等视觉副作用。本研究的目的是通过眼内杂散光来研究多焦点隐形眼镜对失能眩光的影响。

方法

进行了一项前瞻性随机对照研究,纳入16名无眼部病变的受试者。使用商用杂散光仪在自然瞳孔和散瞳状态下测量杂散光。参与者随机佩戴Proclear Multifocal(远用/近用)、ACUVUE Oasys for Presbyopia和Air Optix Aqua Multifocal隐形眼镜,分别佩戴于左眼或右眼。散瞳后在佩戴隐形眼镜的情况下重复测量杂散光。散瞳且不佩戴隐形眼镜时获得的结果作为对照。

结果

自然瞳孔和散瞳后的直径分别为2.87±0.40毫米和7.45±0.86毫米(P<.001)。散瞳后,杂散光从0.92±0.13 log(s)增加到1.04±0.11 log(s)(P<.001)。在所研究的四种镜片中,仅在Air Optix与对照组之间发现了显著差异(P =.006)。后者的光散射也略有增加。

结论

在所研究的多焦点镜片之间发现了测量杂散光的差异。应考虑观察到的变异性和杂散光与瞳孔大小的相关性,以避免多焦点隐形眼镜佩戴者的杂散光升高。观察到的杂散光差异的原因必须是未来研究的主题。