Heat stroke is a medical emergency. Quick diagnosis, and sorting of victims for severity is very important for positive prognosis. Tympanic membrane thermometry was introduced as a good index for core body temperature. Therefore, we have used a sheep model for heat stroke, to study the reliability of measuring body temperature at the tympanic membrane, as a diagnostic index in heat stroke management. This was compared to measuring body temperature at the skin and the rectum. We have observed no major superiority of tympanic over rectal thermometry in regard to its ability to sort out heat stroke cases according to severity. On the other hand, skin thermometry was found not to be a reliable index in this regard.

摘要

中暑是一种医疗急症。快速诊断并根据严重程度对受害者进行分类对于良好的预后非常重要。鼓膜测温法被作为核心体温的一个良好指标引入。因此,我们使用了中暑绵羊模型,来研究在中暑管理中作为诊断指标测量鼓膜体温的可靠性。并将其与测量皮肤和直肠体温进行比较。我们观察到,在根据严重程度区分中暑病例的能力方面,鼓膜测温法相对于直肠测温法并无显著优势。另一方面,在这方面发现皮肤测温法不是一个可靠的指标。