Section of Head and Face Physiology, Department of Biological Sciences, Bauru School of Dentistry, University of São Paulo, Al. Octávio Pinheiro Brisola, 9-75, Bauru, CEP 17012-901, Brazil.
Scandinavian Center for Orofacial Neurosciences (SCON), Aarhus, Denmark.
Clin Oral Investig. 2017 Nov;21(8):2453-2463. doi: 10.1007/s00784-016-2042-6. Epub 2017 Jan 10.
The nociceptive blink reflex (nBR) can be useful to investigate trigeminal nociceptive function. The aim of this study was to estimate the reliability of the nBR evoked by electrical stimulation of the three branches of the trigeminal nerve under the following conditions: over time (test-retest and intrarater reliability) and by two examiners (interrater reliability).
Twenty-one healthy participants were evaluated in two sessions (24 h apart). The nBR was elicited by a so-called "nociceptive-specific" electrode placed over the entry zone of the right supraorbital (V1R), infraorbital (V2R), mental (V3R), and left infraorbital (V2L) nerve. The outcomes were individual electrical sensory (I ) and pain thresholds (I ); root mean square (RMS), area-under-the-curve (AUC), and onset latencies of R2 responses (determined twice after a recalibration session); and stimulus-evoked pain on a 0-10 numerical rating scale. Intraclass correlation coefficients (ICCs) and Kappa statistics were computed (α = 5%).
ICCs were fair to excellent in 82% of the psychophysical measures (fair 21%, good 31%, excellent 30%) and in 86% of V1R, V2R, and V2L nBR parameters, whereas 52% of V3R showed poor reliability. ICCs for intrarater reliability were fair to good in 70% of measurements (fair 20%, good 50%) and in 75% of interrater measurements after the recalibration (fair 55%, good 20%). All kappa values showed at least fair agreement and the majority of the nBR measures (93%) presented moderate to excellent reliability.
The nBR and its associated psychophysical measures can be considered a sufficiently reliable test.
The nBR can be recommended as an electrophysiological technique to assess trigeminal nociceptive function.
伤害性眨眼反射(nBR)可用于研究三叉神经的伤害性感受功能。本研究旨在评估三叉神经三支的电刺激诱发 nBR 在以下情况下的可靠性:随时间变化(测试-重测和内部评估者可靠性)和两名评估者(评估者间可靠性)。
21 名健康参与者在两次评估(相隔 24 小时)中进行评估。nBR 由放置在右侧眶上神经(V1R)、眶下神经(V2R)、颏神经(V3R)和左侧眶下神经(V2L)入口区域的所谓“伤害感受特异性”电极引发。结果为个体电感觉(I)和疼痛阈值(I);均方根(RMS)、曲线下面积(AUC)和 R2 反应的潜伏期(在重新校准后两次确定);以及 0-10 数字评定量表上的刺激诱发疼痛。计算了组内相关系数(ICC)和 Kappa 统计数据(α=5%)。
82%的心理物理测量(21%为一般,31%为良好,30%为优秀)和 86%的 V1R、V2R 和 V2L nBR 参数的 ICC 为良好至优秀,而 V3R 的 52%则表现出较差的可靠性。70%的测量(20%为一般,50%为良好)和重新校准后 75%的评估者间测量(55%为一般,20%为良好)的 ICC 为良好至一般。所有 Kappa 值均显示出至少一般的一致性,大多数 nBR 测量(93%)具有中等至优秀的可靠性。
nBR 及其相关的心理物理测量可被认为是一种足够可靠的测试。
nBR 可被推荐为评估三叉神经伤害性感受功能的电生理技术。