正常成年人使用皮肤电极记录的全视野视网膜电图。

Full-field electroretinogram recorded with skin electrodes in normal adults.

作者信息

Fernandes Arthur Gustavo, Salomão Solange Rios, Pereira Josenilson Martins, Berezovsky Adriana

机构信息

Laboratório de Eletrofisiologia Visual Clínica, Departamento de Oftalmologia e Ciências Visuais, Escola Paulista de Medicina (EPM), Universidade Federal de São Paulo (UNIFESP), São Paulo, SP, Brazil.

出版信息

Arq Bras Oftalmol. 2016 Nov-Dec;79(6):390-394. doi: 10.5935/0004-2749.20160110.

Abstract

PURPOSE

: Alternative recording methods have been tested to allow the electroretinogram (ERG) recording in uncooperative patients and/or patients with palpebral alterations, including recordings with skin electrodes. The purpose of this study was to compare ERG recorded with skin electrodes and well-established microfiber electrodes and to determine normative values of ERG parameters for recording with skin electrodes.

METHODS

: Fifty healthy volunteers (17-26 years; mean 20.63 ± 2.01 years) participated in the study. A gold disk skin electrode was placed on the lower orbital rim of a randomly chosen eye. On the contralateral eye, a microfiber electrode was positioned in the lower conjunctival sac. Gold disc electrodes were positioned at the ipsilateral outer canthus of both eyes acting as reference electrodes for the creation of a potential difference. Two ground electrodes were placed on the lobe of each ear. ERGs were recorded according to the International Society of Clinical Electrophysiology Visual (ISCEV) protocol using the VERIS 5.1.9 system for data acquisition and analysis.

RESULTS

: Both types of electrodes showed similar wave response morphologies. The implicit time of responses between the two electrodes was comparable. On peak-to-peak amplitude, skin electrode recordings showed an amplitude reduction of 61.4% for rod responses, 61.5% for maximal responses, 46.2% for oscillatory potentials, 57.4% for cone responses, and 54.4% for 30Hz-flicker responses, when compared with microfiber electrode recordings. Based on these findings, normative values for peak-to-peak amplitude and implicit time to be used as a reference for ERGs recorded with skin electrodes were determined.

CONCLUSIONS

: ERGs recorded with skin electrodes presented lower peak-to-peak amplitude compared with microfiber electrodes. However, using appropriate normative values, skin electrodes may be useful for specific target populations such as uncooperative infants and/or patients with ocular surface alterations.

摘要

目的

已经对替代记录方法进行了测试,以允许在不合作的患者和/或有眼睑改变的患者中进行视网膜电图(ERG)记录,包括使用皮肤电极进行记录。本研究的目的是比较使用皮肤电极和成熟的微纤维电极记录的ERG,并确定使用皮肤电极记录时ERG参数的正常参考值。

方法

50名健康志愿者(17 - 26岁;平均20.63±2.01岁)参与了本研究。将一个金盘皮肤电极放置在随机选择的一只眼睛的下眼眶边缘。在对侧眼睛,将一个微纤维电极放置在下结膜囊内。金盘电极放置在双眼同侧外眦作为创建电位差的参考电极。两个接地电极分别放置在每只耳朵的耳垂上。根据国际临床视觉电生理学会(ISCEV)协议,使用VERIS 5.1.9系统进行数据采集和分析来记录ERG。

结果

两种类型的电极显示出相似的波响应形态。两个电极之间响应的隐含时间相当。与微纤维电极记录相比,皮肤电极记录在峰峰值幅度上,视杆细胞反应降低了61.4%,最大反应降低了61.5%,振荡电位降低了46.2%,视锥细胞反应降低了57.4%,30Hz闪烁反应降低了54.4%。基于这些发现,确定了峰峰值幅度和隐含时间的正常参考值,以作为使用皮肤电极记录的ERG的参考。

结论

与微纤维电极相比,使用皮肤电极记录的ERG峰峰值幅度较低。然而,使用适当的正常参考值,皮肤电极可能对特定目标人群有用,如不合作的婴儿和/或有眼表改变的患者。