Suppr超能文献

个体间最大摄氧量对运动训练的反应:一项批判性回顾。

Inter-Individual Responses of Maximal Oxygen Uptake to Exercise Training: A Critical Review.

机构信息

Health and Social Care Institute, Teesside University, Middlesbrough, TS1 3BX, UK.

出版信息

Sports Med. 2017 Aug;47(8):1501-1513. doi: 10.1007/s40279-017-0680-8.

Abstract

It has recently been reported how to quantify inter-individual differences in the response to an exercise intervention using the standard deviation of the change scores, as well as how to appraise these differences for clinical relevance. In a parallel-group randomised controlled trial, the key trigger for further investigation into inter-individual responses is when the standard deviation of change in the intervention sample is substantially larger than the same standard deviation derived from a suitable comparator sample. 'True' and clinically relevant inter-individual differences in response can then be plausibly expected, and potential moderators and mediators of the inter-individual differences can be explored. We now aim to critically review the research on the inter-individual differences in response to exercise training, focusing on maximal oxygen uptake (VOmax). A literature search through the relevant bibliographic databases resulted in the identification of six relevant studies that were published prior to the influential HEalth, RIsk factors, exercise Training And GEnetics (HERITAGE) Family Study. Only one of these studies was found to include a comparator arm. Re-analysis of the data from this study, accounting for random within-subjects variation, revealed an absence of clinically important inter-individual differences in the response of VOmax to exercise training. The standard deviation of change was, in fact, larger (±5.6 mL/kg/min) for the comparator than the intervention group (±3.7 mL/kg/min). We located over 180 publications that resulted from the HERITAGE Family Study, but we could not find a comparator arm in any of these studies. Some authors did not explain this absence, while others reasoned that only inter-individual differences in exercise response were of interest, thus the intervention sample was investigated solely. We also found this absence of a comparator sample in on-going studies. A perceived high test-retest reliability is offered as a justification for the absence of a comparator arm, but the test-retest reliability analysis for the HERITAGE Family Study was over a much shorter term than the length of the actual training period between baseline and follow-up measurements of VOmax. We also scrutinised the studies in which twins have been investigated, resulting in concerns about how genetic influences on the magnitude of general within-subjects variability has been partitioned out (again in the absence of a comparator no-training group), as well as with the intra-class correlation coefficient approach to data analysis. Twin pairs were found to be sometimes heterogeneous for the obviously influential factors of sex, age and fitness, thereby inflating an unadjusted coefficient. We conclude that most studies on inter-individual differences in VOmax response to exercise training have no comparator sample. Therefore, true inter-individual differences in response cannot be quantified, let alone appraised for clinical relevance. For those studies with a comparator sample, we found that the inter-individual differences in training response were not larger than random within-subjects variation in VOmax over the same time period as the training intervention.

摘要

最近有报道称,如何使用变化分数的标准差来量化对运动干预的个体间反应差异,以及如何评估这些差异的临床相关性。在一项平行组随机对照试验中,进一步研究个体间反应的关键触发因素是干预样本中变化的标准差明显大于从合适的对照组样本得出的相同标准差。然后可以合理地预期“真实”和临床相关的个体间反应差异,并可以探索个体间差异的潜在调节因素和介导因素。我们现在旨在批判性地回顾关于运动训练反应的个体间差异的研究,重点是最大摄氧量 (VOmax)。通过相关文献数据库进行文献检索,确定了六项在有影响力的健康、风险因素、运动训练和遗传学 (HERITAGE) 家族研究之前发表的相关研究。只有一项研究发现包括对照组。对这项研究的数据进行重新分析,考虑到随机的个体内变异性,发现 VOmax 对运动训练的反应没有临床上重要的个体间差异。变化的标准差实际上更大(±5.6 mL/kg/min),而对照组(±3.7 mL/kg/min)。我们找到了来自 HERITAGE 家族研究的 180 多篇出版物,但我们在这些研究中都没有找到对照组。一些作者没有解释这种缺失,而另一些作者则认为只有运动反应的个体间差异才是有趣的,因此仅对干预样本进行了研究。我们还发现正在进行的研究中也没有对照组样本。有人认为高度的测试-重测可靠性是缺乏对照组的理由,但 HERITAGE 家族研究的测试-重测可靠性分析的时间跨度比 VOmax 的基线和随访测量之间实际训练期短得多。我们还仔细研究了对双胞胎进行研究的研究,对如何将遗传对一般个体内变异性的影响进行分区(再次在没有对照组无训练组的情况下)以及数据分析的组内相关系数方法表示关注。发现双胞胎对性别、年龄和健康等明显影响因素有时存在异质性,从而夸大了未经调整的系数。我们的结论是,大多数关于 VOmax 对运动训练反应的个体间差异的研究都没有对照组样本。因此,无法量化真正的个体间反应差异,更不用说评估其临床相关性了。对于那些有对照组样本的研究,我们发现训练反应的个体间差异并不大于 VOmax 在与训练干预相同时间段内的个体内变异性。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验