Destrempes François, Roy Cardinal Marie-Hélène, Saijo Yoshifumi, Finet Gérard, Tardif Jean-Claude, Cloutier Guy
Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center (CRCHUM), Montreal, Québec, Canada.
Department of Biomedical Engineering and Cardiology, Tohoku University, Sendai, Japan.
PLoS One. 2017 Jan 20;12(1):e0168332. doi: 10.1371/journal.pone.0168332. eCollection 2017.
The objectives were to compare the performance of a segmentation algorithm, based on the minimization of an uncertainty function, to delineate contours of external elastic membrane and lumen of human coronary arteries imaged with 40 and 60 MHz IVUS, and to use values of this function to delineate portions of contours with highest uncertainty. For 8 patients, 40 and 60 MHz IVUS coronary data acquired pre- and post-interventions were used, for a total of 68,516 images. Manual segmentations of contours (on 2312 images) performed by experts at three core laboratories were the gold-standards. Inter-expert variability was highest on contour points with largest values of the uncertainty function (p < 0.001). Inter-expert variability was lower at 60 than 40 MHz for external elastic membrane (p = 0.013) and lumen (p = 0.024). Average differences in plaque (and atheroma) burden between algorithmic contours and experts' contours were within inter-expert variability (p < 0.001).
目的是比较一种基于最小化不确定性函数的分割算法在描绘用40兆赫和60兆赫血管内超声(IVUS)成像的人体冠状动脉外弹性膜和管腔轮廓方面的性能,并使用该函数的值来描绘具有最高不确定性的轮廓部分。对于8名患者,使用了干预前后采集的40兆赫和60兆赫IVUS冠状动脉数据,共计68516幅图像。由三个核心实验室的专家进行的轮廓手动分割(在2312幅图像上)作为金标准。在不确定性函数值最大的轮廓点上,专家间的变异性最高(p<0.001)。对于外弹性膜(p = 0.013)和管腔(p = 0.024),60兆赫时专家间的变异性低于40兆赫。算法轮廓与专家轮廓之间斑块(和动脉粥样瘤)负荷的平均差异在专家间变异性范围内(p<0.001)。