*Pavia nel Cuore,IRC-Comunità Training Center,Pavia,Italy.
CJEM. 2017 Nov;19(6):480-487. doi: 10.1017/cem.2016.410. Epub 2017 Jan 24.
The chances of surviving an out-of-hospital cardiac arrest depend on early and high-quality cardiopulmonary resuscitation (CPR). Our aim is to verify whether the use of feedback devices during laypersons' CPR training improves chest compression quality.
Laypersons totalling 450 participating in Basic Life Support and Automated External Defibrillation (BLS/AED) courses were randomly divided into three groups: group No Feedback (NF) attended a course without any feedback, group Short Feedback (SF) a course with 1-minute training with real-time visual feedback, and group Long Feedback (LF) a course with 10-minute training with real-time visual feedback. At the end of each course, we recorded 1 minute of compression-only CPR. The primary end point was the difference in the percentage of compressions performed with correct depth.
There was a significant improvement in the percentage of compressions with correct depth in the groups receiving feedback compared to the other (NF v. LF, p=0.022; NF v. SF, p=0.005). This improvement was also present in the percentage of compressions with a complete chest recoil (71.7% in NF, 86.6% in SF, and 88.8% in LF; p<0.001), compressions with the correct hand position (93.2% in NF, 98.2% in SF, and 99.3% in LF; p<0.001), and in the Total CPR Score (79.4% in NF, 90.2% in SF, and 92.5% in LF; p<0.001). There were no significant differences for all of the parameters between group SF and group LF.
Real-time visual feedback improves laypersons' CPR quality, and we suggest its use in every BLS/AED course for laypersons because it can help achieve the goals emphasized by the International Liaison Committee on Resuscitation recommendations.
院外心脏骤停患者的存活机会取决于早期和高质量的心肺复苏(CPR)。我们的目的是验证在非专业人员的 CPR 培训中使用反馈设备是否能提高胸外按压质量。
共有 450 名参与基础生命支持和自动体外除颤器(BLS/AED)课程的非专业人员被随机分为三组:无反馈组(NF)参加无任何反馈的课程,短反馈组(SF)参加 1 分钟实时视觉反馈培训课程,长反馈组(LF)参加 10 分钟实时视觉反馈培训课程。在每个课程结束时,我们记录 1 分钟仅按压的 CPR。主要终点是正确按压深度的按压比例差异。
与无反馈组相比,接受反馈的组的正确按压深度百分比有显著提高(NF 与 LF 相比,p=0.022;NF 与 SF 相比,p=0.005)。在完全胸壁回弹的按压百分比(NF 为 71.7%,SF 为 86.6%,LF 为 88.8%;p<0.001)、正确手位的按压百分比(NF 为 93.2%,SF 为 98.2%,LF 为 99.3%;p<0.001)和总 CPR 评分(NF 为 79.4%,SF 为 90.2%,LF 为 92.5%;p<0.001)方面,SF 组和 LF 组之间也存在显著差异。SF 组和 LF 组之间所有参数均无显著差异。
实时视觉反馈提高了非专业人员的 CPR 质量,我们建议在每个非专业人员的 BLS/AED 课程中使用它,因为它可以帮助实现国际复苏联络委员会推荐强调的目标。