激光辅助晶状体囊切开术的中心定位:一项比较基于瞳孔与基于光学相干断层扫描的扫描囊膜中心定位的前瞻性试验。

Laser-Assisted Capsulotomy Centration: A Prospective Trial Comparing Pupil Versus OCT-Based Scanned Capsule Centration.

作者信息

Schultz Tim, Tsiampalis Nikolaos, Dick H Burkhard

出版信息

J Refract Surg. 2017 Feb 1;33(2):74-78. doi: 10.3928/1081597X-20161219-01.

Abstract

PURPOSE

To investigate different capsulotomy centration methods for femtosecond laser-assisted cataract surgery. The overlap between intraocular lens (IOL) optic and lens capsule was measured with different centration methods and IOL types.

METHODS

This was a prospective randomized clinical trial. Patients with cataract scheduled for femtosecond laser-assisted cataract surgery were assigned to one of four treatment groups: optical coherence tomography (OCT)-based scanned capsule centration (SCC) and three-piece IOL (SCC with three-piece IOL); scanned capsule centration and plate-haptic IOL (SCC with plate-haptic IOL); pupil centration (PC) and three-piece IOL (PC with three-piece IOL); or PC and plate-haptic IOL (PC with plate-haptic IOL). At the end of surgery, the overlap between the IOL optic and capsular bag was measured.

RESULTS

The results of 160 patients were evaluated (n = 40 in each group). There was no difference in age (P = .27), sex (P = .18), the number of treated left and right eyes (P = .64), or cataract grade (P = .06). With the new SCC method (capsulotomy diameter: 5 mm), a complete overlap was achieved in all cases in both SCC groups. The overlap was also complete in all cases with PC and plate-haptic IOLs. In the PC with three-piece IOL group, the overlap was incomplete in 3 eyes.

CONCLUSIONS

The SCC method helps to achieve a 360° overlap in all eyes independent of the IOL type. A complete 360° overlap was achieved in all cases up to a calculated capsulotomy diameter of 5.1 mm with this new method. [J Refract Surg. 2017;33(2):74-78.].

摘要

目的

研究飞秒激光辅助白内障手术中不同的撕囊中心定位方法。采用不同的中心定位方法和人工晶状体(IOL)类型测量眼内晶状体光学部与晶状体囊膜之间的重叠情况。

方法

这是一项前瞻性随机临床试验。计划接受飞秒激光辅助白内障手术的白内障患者被分配到四个治疗组之一:基于光学相干断层扫描(OCT)的扫描撕囊中心定位(SCC)和三件式IOL(SCC联合三件式IOL);扫描撕囊中心定位和平板襻IOL(SCC联合平板襻IOL);瞳孔中心定位(PC)和三件式IOL(PC联合三件式IOL);或PC和平板襻IOL(PC联合平板襻IOL)。手术结束时,测量IOL光学部与囊袋之间的重叠情况。

结果

对160例患者的结果进行了评估(每组n = 40)。年龄(P = 0.27)、性别(P = 0.18)、治疗的左右眼数量(P = 0.64)或白内障分级(P = 0.06)方面无差异。采用新的SCC方法(撕囊直径:5 mm),两个SCC组的所有病例均实现了完全重叠。PC联合平板襻IOL的所有病例也实现了完全重叠。在PC联合三件式IOL组中,3只眼的重叠不完全。

结论

SCC方法有助于在所有眼中实现360°重叠,与IOL类型无关。采用这种新方法,在计算撕囊直径达5.1 mm的所有病例中均实现了完全的360°重叠。[《屈光手术杂志》。2017;33(2):74 - 78。]