Abstract

. To evaluate the effects of fixture design and surface on the early bone formation around immediately loaded implants inserted in the human posterior maxilla. . Ten totally edentulous subjects received two transitional implants: one tapered implant with knife-edge threads/nanostructured calcium-incorporated surface (test: Anyridge®, Megagen, Gyeongbuk, South Korea) and one cylindrical implant with self-tapping threads/sandblasted surface (control: EZPlus®, Megagen). The implants were placed according to a split-mouth design and immediately loaded to support an interim complete denture; after 8 weeks, they were removed for histologic/histomorphometric analysis. The bone-to-implant contact (BIC%) and the bone density (BD%) were calculated. The Wilcoxon test was used to evaluate the differences. . With test implants, a mean BIC% and BD% of 35.9 (±9.1) and 31.8 (±7.5) were found. With control implants, a mean BIC% and BD% of 29.9 (±7.6) and 32.5 (±3.9) were found. The mean BIC% was higher with test implants, but this difference was not significant ( = 0.16). Similar BD% were found in the two groups ( = 0.9). . In the posterior maxilla, under immediate loading conditions, implants with a knife-edge thread design/nanostructured calcium-incorporated surface seem to increase the peri-implant endosseous healing properties, when compared to implants with self-tapping thread design/sandblasted surface.

摘要

评估种植体设计和表面对即刻负载植入于人类上颌后牙区的种植体周围早期骨形成的影响。10名全口无牙颌受试者接受了两颗过渡性种植体:一颗带有刃状螺纹/纳米结构含钙化表面的锥形种植体(试验组:Anyridge®,韩国庆尚北道 Megagen公司)和一颗带有自攻螺纹/喷砂表面的圆柱形种植体(对照组:EZPlus®,Megagen公司)。种植体按照分口设计植入,并即刻负载以支持一副临时全口义齿;8周后,将种植体取出进行组织学/组织形态计量学分析。计算骨-种植体接触率(BIC%)和骨密度(BD%)。采用 Wilcoxon 检验评估差异。试验组种植体的平均 BIC%和 BD%分别为 35.9(±9.1)和 31.