Faramarzi Amir, Feizi Sepehr, Maghsoodlou Ali
Ophthalmic Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
Br J Ophthalmol. 2017 Nov;101(11):1493-1499. doi: 10.1136/bjophthalmol-2016-310077. Epub 2017 Mar 28.
This study aims to compare intraocular pressure (IOP), central corneal thickness (CCT) and corneal biomechanics among patients with aphakia, patients with primary and secondary pseudophakia and matched controls following congenital cataract surgery and to investigate the factors influencing these variables.
This study included 36 aphakic eyes, 47 primary pseudophakic eyes and 30 secondary pseudophakic eyes. Thirty-four normal eyes of matched volunteers were recruited for comparisons. Postoperative IOP measured with a Goldmann applanation tonometer (IOP), CCT, corneal hysteresis (CH), corneal resistance factor (CRF) and cornea-compensated IOP (IOP) were compared among the groups. Univariate analyses and multiple linear regression analyses were used to investigate the influences of independent factors on IOP, CCT, CH, CRF and IOP, considering all the operated eyes as one group.
IOP was 12.5±0.92, 14.7±1.9, 13.4±2.3 and 15.7±2.0 mm Hg in normal, aphakic, primary pseudophakic and secondary pseudophakic eyes, respectively (p<0.001). CCT was 559.5±42.7, 628.0±61.7, 566.8±35.3 and 585.2±41.1 µm, respectively (p<0.001). CH was 10.87±2.47, 10.42±2.20, 11.84±2.13 and 9.74±1.94 mm Hg, respectively (p=0.019). IOP was 15.91±3.74, 18.40±4.35, 14.58±4.36 and 19.05±4.54 mm Hg, respectively (p<0.001). There was no significant difference in CRF among the groups (p=0.06). Regression analyses revealed that the type of operation was significantly associated with IOP (p=0.04), CCT (p<0.001) and CH (p=0.006).
IOP, CCT, CH and IOP were significantly different in treated eyes compared with normal eyes after congenital cataract surgery. These variables were primarily affected by the type of surgery. Primary intraocular lens implantation preserved corneal structure and function of the anterior chamber angle.
本研究旨在比较无晶状体眼患者、原发性和继发性人工晶状体眼患者以及先天性白内障手术后匹配对照组的眼压(IOP)、中央角膜厚度(CCT)和角膜生物力学,并研究影响这些变量的因素。
本研究纳入了36只无晶状体眼、47只原发性人工晶状体眼和30只继发性人工晶状体眼。招募了34名匹配志愿者的正常眼睛进行比较。比较各组使用Goldmann压平眼压计测量的术后眼压(IOP)、CCT、角膜滞后(CH)、角膜阻力因子(CRF)和角膜补偿眼压(IOP)。采用单因素分析和多元线性回归分析,将所有手术眼视为一组,研究独立因素对IOP、CCT、CH、CRF和IOP的影响。
正常眼、无晶状体眼、原发性人工晶状体眼和继发性人工晶状体眼的IOP分别为12.5±0.92、14.7±1.9、13.4±2.3和15.7±2.0 mmHg(p<0.001)。CCT分别为559.5±42.7、628.0±61.7、566.8±35.3和585.2±41.1 µm(p<0.001)。CH分别为10.87±2.47、10.42±2.20、11.84±2.13和9.74±1.94 mmHg(p=0.019)。IOP分别为15.91±3.74、18.40±4.35、14.58±4.36和19.05±4.54 mmHg(p<0.001)。各组间CRF无显著差异(p=0.06)。回归分析显示,手术类型与IOP(p=0.04)、CCT(p<0.001)和CH(p=0.006)显著相关。
与先天性白内障手术后的正常眼相比,治疗眼的IOP、CCT、CH和IOP有显著差异。这些变量主要受手术类型的影响。一期人工晶状体植入保留了角膜结构和前房角功能。