单扫描静息/负荷成像:氟[18F]氟吡拉赞猪模型验证。

Single-scan rest/stress imaging: validation in a porcine model with F-Flurpiridaz.

机构信息

Gordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.

Cardiac Arrhythmia Service, Department of Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA, 02114, USA.

出版信息

Eur J Nucl Med Mol Imaging. 2017 Aug;44(9):1538-1546. doi: 10.1007/s00259-017-3684-6. Epub 2017 Apr 1.

Abstract

PURPOSE

F-labeled myocardial flow agents are becoming available for clinical application but the ∼2 hour half-life of F complicates their clinical application for rest-stress measurements. The goal of this work is to evaluate in a pig model a single-scan method which provides quantitative rest-stress blood flow in less than 15 minutes.

METHODS

Single-scan rest-stress measurements were made using F-Flurpiridaz. Nine scans were performed in healthy pigs and seven scans were performed in injured pigs. A two-injection, single-scan protocol was used in which an adenosine infusion was started 4 minutes after the first injection of F-Flurpiridaz and followed either 3 or 6 minutes later by a second radiotracer injection. In two pigs, microsphere flow measurements were made at rest and during stress. Dynamic images were reoriented into the short axis view, and regions of interest (ROIs) for the 17 myocardial segments were defined in bull's eye fashion. PET data were fitted with MGH2, a kinetic model with time varying kinetic parameters, in which blood flow changes abruptly with the introduction of adenosine. Rest and stress myocardial blood flow (MBF) were estimated simultaneously.

RESULTS

The first 12-14 minutes of rest-stress PET data were fitted in detail by the MGH2 model, yielding MBF measurement with a mean precision of 0.035 ml/min/cc. Mean myocardial blood flow across pigs was 0.61 ± 0.11 mL/min/cc at rest and 1.06 ± 0.19 mL/min/cc at stress in healthy pigs and 0.36 ± 0.20 mL/min/cc at rest and 0.62 ± 0.24 mL/min/cc at stress in the ischemic area. Good agreement was obtained with microsphere flow measurement (slope = 1.061 ± 0.017, intercept = 0.051 ± 0.017, mean difference 0.096 ± 0.18 ml/min/cc).

CONCLUSION

Accurate rest and stress blood flow estimation can be obtained in less than 15 min of PET acquisition. The method is practical and easy to implement suggesting the possibility of clinical translation.

摘要

目的

F 标记的心肌血流示踪剂正逐渐应用于临床,但 F 的半衰期约为 2 小时,这使得其在静息-负荷测量中的临床应用变得复杂。本研究的目的是在猪模型中评估一种可在 15 分钟内提供定量静息-负荷血流的单次扫描方法。

方法

使用 F-Flurpiridaz 进行单次扫描静息-负荷测量。在健康猪中进行了 9 次扫描,在损伤猪中进行了 7 次扫描。采用双注射、单次扫描方案,在首次注射 F-Flurpiridaz 后 4 分钟开始腺苷输注,随后 3 或 6 分钟后再次注射示踪剂。在两只猪中,在静息和应激期间进行微球血流测量。动态图像被重新定向到短轴视图,并以牛眼方式定义 17 个心肌节段的感兴趣区(ROI)。PET 数据采用 MGH2 进行拟合,MGH2 是一个具有时变动力学参数的动力学模型,其中血流在腺苷引入时突然发生变化。同时估计静息和应激心肌血流(MBF)。

结果

MGH2 模型详细拟合了静息-负荷 PET 数据的前 12-14 分钟,得出 MBF 测量的平均精度为 0.035ml/min/cc。健康猪的平均静息和应激心肌血流分别为 0.61±0.11ml/min/cc 和 1.06±0.19ml/min/cc,缺血区分别为 0.36±0.20ml/min/cc 和 0.62±0.24ml/min/cc。与微球血流测量结果吻合良好(斜率=1.061±0.017,截距=0.051±0.017,平均差异为 0.096±0.18ml/min/cc)。

结论

在 PET 采集不到 15 分钟的时间内,可以准确估计静息和应激血流。该方法实用且易于实施,提示其具有临床转化的可能性。