Ayala Marcelo, Karlsson Johanna
Eye Department, Skaraborg Hospital, Skövde, Sahlgrenska Academy, Gothenburg University and Karolinska Institute.
Faculty of Medicine, Örebro University, Örebro, Sweden.
Clin Ophthalmol. 2017 Apr 19;11:733-738. doi: 10.2147/OPTH.S136007. eCollection 2017.
Measurements of intraocular pressure (IOP) with Goldmann applanation tonometry are affected by central corneal thickness (CCT), as thinner corneas underestimate and thicker corneas overestimate the true IOP value. The literature is controversial regarding CCT values in patients with primary open-angle glaucoma (POAG) and exfoliation glaucoma (XFG). The aim of this study was to evaluate CCT in patients with XFG and POAG.
CCT was evaluated with optical coherence tomography (OCT). All participants who were previously diagnosed with either POAG or XFG underwent ophthalmological examinations. Contact lens users and patients with corneal diseases were excluded.
Totally, 145 patients were enrolled in this study. The mean CCT was 535±30.4 µm in patients with POAG and was 536±33.7 µm in patients with XFG. The result was not statistically significant (=0.98). The mean age for all participants was 73.8±7.7 years. The study included totally 61 women and 84 men. The two groups were similar in their demographic data, and mean deviation was the only parameter that differed statistically when comparing POAG with XFG (=0.02).
Our data indicate that patients with XFG do not have thinner corneas than those with POAG, and therefore, CCT can not explain why they progress differently.
使用Goldmann压平眼压计测量眼压(IOP)会受到中央角膜厚度(CCT)的影响,角膜较薄会低估真实眼压值,而角膜较厚则会高估真实眼压值。关于原发性开角型青光眼(POAG)和剥脱性青光眼(XFG)患者的CCT值,文献存在争议。本研究的目的是评估XFG和POAG患者的CCT。
使用光学相干断层扫描(OCT)评估CCT。所有先前被诊断为POAG或XFG的参与者均接受眼科检查。排除隐形眼镜使用者和角膜疾病患者。
本研究共纳入145例患者。POAG患者的平均CCT为535±30.4 µm,XFG患者的平均CCT为536±33.7 µm。结果无统计学意义(P=0.98)。所有参与者的平均年龄为73.8±7.7岁。该研究共包括61名女性和84名男性。两组的人口统计学数据相似,在比较POAG和XFG时,平均偏差是唯一具有统计学差异的参数(P=0.02)。
我们的数据表明,XFG患者的角膜并不比POAG患者的角膜薄,因此,CCT无法解释它们为何进展不同。