A resonance frequency analysis of sandblasted and acid-etched implants with different diameters: a prospective clinical study during the initial healing period.

作者信息

Kim Hyun-Joo, Kim Yeun-Kang, Joo Ji-Young, Lee Ju-Youn

机构信息

Department of Periodontology and Dental Research Institute, Pusan National University Dental Hospital, Yangsan, Korea.

Department of Periodontology and Institute of Translational Dental Sciences, Pusan National University School of Dentistry, Yangsan, Korea.

出版信息

J Periodontal Implant Sci. 2017 Apr;47(2):106-115. doi: 10.5051/jpis.2017.47.2.106. Epub 2017 Apr 29.

Abstract

PURPOSE

The possibility of immediate or early loading has become popular in implant dentistry. A prerequisite for the immediate or early loading of an implant prosthesis is the achievement of initial stability in the implant. Moreover, in response to clinicians' interest in verifying clinical stability to determine the optimal time point for functional loading, a non-invasive method to assess implant stability has been developed on the basis of resonance frequency analysis (RFA). The primary objective of this study was to monitor the stability of sandblasted, large-grit, and acid-etched (SLA) implants with different diameters during the early phases of healing by RFA. The secondary objective was to evaluate how the initial stability of implants varied depending on different surface modifications and other contributing factors.

METHODS

Thirty-five implants (25 SLA implants and 10 resorbable blasting media [RBM] implants) placed in 20 subjects were included. To measure implant stability, RFA was performed at baseline and at 1, 2, 3, 4, 6, and 10 weeks after surgery.

RESULTS

The longitudinal changes in the implant stability quotient (ISQ) values were similar for the SLA implants with different diameters and for the RBM implants. During the initial healing period, the ISQ decreased after installation and reached its lowest values at 1 week and 2 weeks, respectively. The mean ISQ values in the SLA implants were significantly higher in Ø 5.0 mm implants than in Ø 4.0 mm implants. Men showed a higher ISQ than women. Mandibular sites showed a higher ISQ than maxillary sites.

CONCLUSIONS

All implants used in this study are suitable for immediate or early loading under appropriate indications. A wider diameter and SLA surface treatment of implants could improve the stability, if the implant is fixed with at least 30 Ncm of insertion torque.

摘要

目的

即刻或早期负重的可能性在种植牙科中已变得流行。种植修复体即刻或早期负重的一个前提是种植体获得初始稳定性。此外,为响应临床医生对验证临床稳定性以确定功能负重最佳时间点的兴趣,基于共振频率分析(RFA)开发了一种评估种植体稳定性的非侵入性方法。本研究的主要目的是通过RFA监测不同直径的喷砂、大颗粒酸蚀(SLA)种植体在愈合早期阶段的稳定性。次要目的是评估种植体的初始稳定性如何因不同的表面处理和其他影响因素而变化。

方法

纳入了放置在20名受试者中的35枚种植体(25枚SLA种植体和10枚可吸收喷砂介质[RBM]种植体)。为测量种植体稳定性,在基线以及术后1、2、3、4、6和10周进行RFA。

结果

不同直径的SLA种植体和RBM种植体的种植体稳定性商数(ISQ)值的纵向变化相似。在初始愈合期,植入后ISQ下降,分别在第1周和第2周达到最低值。Ø 5.0 mm的SLA种植体的平均ISQ值显著高于Ø 4.0 mm的种植体。男性的ISQ高于女性。下颌部位的ISQ高于上颌部位。

结论

本研究中使用的所有种植体在适当的适应证下都适合即刻或早期负重。如果种植体以至少30 Ncm的植入扭矩固定,更大的直径和SLA表面处理可提高稳定性。