Suppr超能文献

三次计时起立行走测试的可靠性

Reliability of the triple-timed up-and-go test.

作者信息

Sanders Donald B, Guptill Jeffrey T, Aleš Kathy L, Hobson-Webb Lisa D, Jacobus David P, Mahmood Riaz, Massey Janice M, Pittman Melissa M, Prather Kristi, Raja Shruti M, Yow Eric, Juel Vern C

机构信息

Neuromuscular Section, Department of Neurology, Duke University Medical Center, Box 3403, Durham, North Carolina, 27710, USA.

Jacobus Pharmaceutical Company, Princeton, New Jersey, USA.

出版信息

Muscle Nerve. 2018 Jan;57(1):136-139. doi: 10.1002/mus.25700. Epub 2017 Jun 6.

Abstract

INTRODUCTION

We report the reliability of a new measure, the triple-timed up-and-go (3TUG) test, for assessing clinical function in patients with Lambert-Eaton myasthenia (LEM).

METHODS

Intrarater reproducibility and interrater agreement of the 3TUG test were assessed in 25 control participants, 24 patients with non-LEM neuromuscular disease, and 12 patients with LEM. The coverage probability (CP) method was the primary measure of reproducibility and agreement. The a priori acceptable range was < 20% difference in 3TUG test times and a CP ≥0.90 confirmed agreement.

RESULTS

CP values > 0.90 for intrarater and interrater tests confirmed acceptable reproducibility and agreement for all groups.

DISCUSSION

The 3TUG test is a quick, noninvasive, and reproducible measure that is easy to perform, measures clinically important weakness in LEM patients, and requires little training. Additional evaluation in a larger number of LEM patients is in progress to validate the 3TUG test as a clinical measure in LEM. Muscle Nerve 57: 136-139, 2017.

摘要

引言

我们报告了一种新的测量方法——三次计时起立行走(3TUG)测试,用于评估兰伯特-伊顿肌无力(LEM)患者的临床功能。

方法

在25名对照参与者、24名非LEM神经肌肉疾病患者和12名LEM患者中评估3TUG测试的评分者内再现性和评分者间一致性。覆盖概率(CP)方法是再现性和一致性的主要测量指标。先验可接受范围为3TUG测试时间差异<20%,且CP≥0.90可确认一致性。

结果

评分者内和评分者间测试的CP值>0.90,证实所有组的再现性和一致性均可接受。

讨论

3TUG测试是一种快速、无创且可重复的测量方法,易于实施,可测量LEM患者临床上重要的肌无力,且几乎无需培训。目前正在对更多LEM患者进行进一步评估,以验证3TUG测试作为LEM临床测量方法的有效性。《肌肉与神经》57: 136 - 139, 2017年。

相似文献

1
Reliability of the triple-timed up-and-go test.三次计时起立行走测试的可靠性
Muscle Nerve. 2018 Jan;57(1):136-139. doi: 10.1002/mus.25700. Epub 2017 Jun 6.
5
Treatment for Lambert-Eaton myasthenic syndrome.兰伯特-伊顿肌无力综合征的治疗。
Cochrane Database Syst Rev. 2003(2):CD003279. doi: 10.1002/14651858.CD003279.
7
Clinical neurophysiology of disorders of the neuromuscular junction.神经肌肉接头疾病的临床神经生理学
J Clin Neurophysiol. 1993 Apr;10(2):167-80. doi: 10.1097/00004691-199304000-00004.
8
Lambert-Eaton myasthenic syndrome in children.儿童兰伯特-伊顿肌无力综合征
J Child Neurol. 2002 Jan;17(1):74-6. doi: 10.1177/088307380201700123.

引用本文的文献

1
Do we know about dynapenia?我们了解肌肉减少症吗?
North Clin Istanb. 2024 Nov 22;11(6):593-599. doi: 10.14744/nci.2024.48642. eCollection 2024.

本文引用的文献

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验