Suppr超能文献

在六分钟步行试验和递增式跑步机心肺运动试验期间,对男性慢性阻塞性肺疾病患者的呼吸困难和动态肺过度充气情况进行评估。

Assessment of dyspnea and dynamic hyperinflation in male patients with chronic obstructive pulmonary disease during a six minute walk test and an incremental treadmill cardiorespiratory exercise test.

作者信息

Alfonso M, Bustamante V, Cebollero P, Antón M, Herrero S, Gáldiz J B

机构信息

Servicio de Neumología, Complejo Hospitalario de Navarra, Osasunbidea, Pamplona, Spain.

Departamento de Medicina, Servicio de Neumología, Hospital Universitario Basurto, Osakidetza, EHU-Universidad del País Vasco, Vizcaya, Spain.

出版信息

Rev Port Pneumol (2006). 2017 Sep-Oct;23(5):266-272. doi: 10.1016/j.rppnen.2017.04.007. Epub 2017 Jun 2.

Abstract

UNLABELLED

The six minute walk test (6MWT) is a standardized test that provides information on exercise capacity in patients with COPD. It is considered a submaximal test in opposition to incremental cardiopulmonary exercise tests (CPET) that provide valuable information on all the systems involved in exercise.

OBJECTIVES

  1. To compare the perceptive, physiological responses and degree of dynamic hyperinflation during two exercise tests: the 6MWT and the incremental CPET on a treadmill. 2. To evaluate how dyspnea is related to dynamic hyperinflation (DH) and other functional parameters in both tests.

METHODS

29 stable COPD male patients, age 68±5.8 years, mean post-bronchodilator FEV1 57±11%, were recruited. To evaluate dynamic hyperinflation, inspiratory capacity (IC) was measured at rest and upon completing each one of the tests. At the same time, perceived dyspnea and leg discomfort were rated on specific modified Borg scales.

RESULTS

The mean walk distance in 6MWT was 494±88m. The Borg scale rating for shortness of breath upon completing the test was 4.7±2, whilst 2.9±2 for leg discomfort. IC changed from 2.53±0.63l before to 2.34±0.60l after completion of the test. In the treadmill CPET, maximal oxygen consumption (V˙Omax) was 21.8±5mL/kg/min with 6.6±2 dyspnea and 4.3±2 leg discomfort on Borg scales. IC changed from 2.17±0.53l to 1.20±0.43l.

CONCLUSIONS

Dynamic hyperinflation occurs in male COPD patients during submaximal exercise such as the 6MWT. This phenomenon is more pronounced after incremental CPET on a treadmill. Despite being dyspnea the dominant limiting symptom for both tests, we observed different physiological responses.

摘要

未标注

六分钟步行试验(6MWT)是一项标准化测试,可提供慢性阻塞性肺疾病(COPD)患者运动能力的相关信息。与递增心肺运动试验(CPET)相反,它被认为是一项次极量测试,CPET能提供有关运动中所有参与系统的有价值信息。

目的

  1. 比较在两项运动测试中,即6MWT和跑步机递增CPET期间的感知、生理反应及动态肺过度充气程度。2. 评估在两项测试中呼吸困难与动态肺过度充气(DH)及其他功能参数之间的关系。

方法

招募了29名稳定期COPD男性患者,年龄68±5.8岁,支气管扩张剂使用后FEV1平均值为57±11%。为评估动态肺过度充气,在静息时以及完成每项测试后测量吸气容量(IC)。同时,使用特定的改良Borg量表对感知到的呼吸困难和腿部不适进行评分。

结果

6MWT中的平均步行距离为494±88米。完成测试时气短的Borg量表评分为4.7±2,而腿部不适评分为2.9±2。IC从测试前的2.53±0.63升变为测试后的2.34±0.60升。在跑步机CPET中,最大摄氧量(V˙Omax)为21.8±5毫升/千克/分钟,Borg量表上的呼吸困难评分为6.6±2,腿部不适评分为4.3±2。IC从2.17±0.53升变为1.20±0.43升。

结论

在次极量运动如6MWT期间,男性COPD患者会出现动态肺过度充气。这种现象在跑步机递增CPET后更为明显。尽管呼吸困难是两项测试的主要限制症状,但我们观察到了不同的生理反应。