Carruthers Jean D, Humphrey Shannon, Rivers Jason K
*Carruthers & Humphrey Cosmetic Dermatology Clinic, Vancouver, British Columbia, Canada; Departments of †Ophthalmology, and ‡Dermatology and Skin Science, University of British Columbia, Vancouver, British Columbia, Canada; §Pacific Dermaesthetics, Vancouver, British Columbia, Canada.
Dermatol Surg. 2017 Jul;43(7):940-949. doi: 10.1097/DSS.0000000000001134.
Cryolipolysis of the arms has been shown to be an effective but somewhat time-consuming process.
The study evaluated safety and efficacy of a contoured cup cryolipolysis applicator for reduction of arm fat. The prototype was designed to maximize tissue contact with the cooling surface to improve comfort, while reducing treatment time by 25 minutes.
Both arms were treated using a prototype device that delivered treatment in 35 minutes at -11°C. Photographic and ultrasound documentation was captured at baseline and 12 weeks post-treatment. Efficacy was assessed by photo review and measurement of fat reduction in ultrasound images. Immediately after 1, 4, and 12 weeks post-treatment, clinical assessments were performed to evaluate treatment areas and sensory alterations.
Thirty women were enrolled and completed treatments to both arms. Ultrasound measurements found mean fat layer reduction of 3.2 mm with an SD of 2.7 mm. Blinded independent photo review found 85.2% correct identification of baseline photographs by at least 2/3 of reviewers. There were no unanticipated adverse device effects. Four study subjects experienced numbness in the treatment area beyond the 12-week visit that subsequently resolved without intervention.
These data suggest that the CoolCup prototype applicator provides rapid, safe, and effective arm treatment.
手臂冷冻溶脂术已被证明是一种有效的但有点耗时的过程。
本研究评估了一种轮廓贴合杯状冷冻溶脂治疗器减少手臂脂肪的安全性和有效性。该原型设计旨在最大限度地增加组织与冷却表面的接触,以提高舒适度,同时将治疗时间缩短25分钟。
使用原型设备对双臂进行治疗,该设备在-11°C下35分钟内完成治疗。在基线和治疗后12周拍摄照片并进行超声记录。通过照片评估和超声图像中脂肪减少的测量来评估疗效。在治疗后1周、4周和12周后立即进行临床评估,以评估治疗区域和感觉改变。
30名女性入组并完成了双臂治疗。超声测量发现平均脂肪层减少3.2mm,标准差为2.7mm。盲法独立照片评估发现,至少2/3的评估者能正确识别85.2%的基线照片。没有出现意外的器械不良影响。4名研究对象在12周随访后治疗区域出现麻木,随后未经干预自行缓解。
这些数据表明,CoolCup原型治疗器可提供快速、安全且有效的手臂治疗。