Suppr超能文献

作为肺毛细血管楔压无创标志物的 HVAD 波形分析:迈向智能左心室辅助装置泵开发的第一步。

HVAD Waveform Analysis as a Noninvasive Marker of Pulmonary Capillary Wedge Pressure: A First Step Toward the Development of a Smart Left Ventricular Assist Device Pump.

作者信息

Grinstein Jonathan, Rodgers Daniel, Kalantari Sara, Sayer Gabriel, Kim Gene H, Sarswat Nitasha, Adatya Sirtaz, Ota Takeyoshi, Jeevanandam Valluvan, Burkhoff Daniel, Uriel Nir

出版信息

ASAIO J. 2018 Jan/Feb;64(1):10-15. doi: 10.1097/MAT.0000000000000604.

Abstract

Flow waveforms are an important feature of the HVAD left ventricular assist device (LVAD) that provides information about HVAD function and patient hemodynamics. We assessed the properties of one specific aspect of the waveform, the slope of the ventricular filling phase (VFP), and its correlation with pulmonary capillary wedge pressure (PCWP). A total of 101 screenshots from the HVAD monitor and simultaneous hemodynamic measurements were obtained simultaneously during sequential stages of invasive hemodynamic ramp studies. Each screenshot was digitized (IGOR Pro, WaveMetrics Inc., Oswego, OR) and properties of the flow waveforms including instantaneous flow and rate of change of flow were analyzed. Ventricular filling phase slope (VFPS) was calculated for each screenshot and correlated to PCWP. Ventricular filling phase slope was significantly higher in patients with PCWP ≥ 18 mm Hg than in patients with PCWP < 18 mm Hg [6.25 (5.84-7.37) L/min/s vs. 3.27 (2.00-4.69) L/min/s, p ≤ 0.0001]. A VFPS threshold of 5.8 L/min/s predicted a PCWP ≥ 18 mm Hg with a sensitivity of 87% and specificity of 95% (AUC 0.95). Ventricular filling phase slope of the HVAD flow waveform is a novel noninvasive parameter that correlates with PCWP and can discriminate elevated versus normal or low PCWP. Automated reporting of this parameter may help clinical assessment and management of patients supported by an HVAD and may serve as the basis of a smart LVAD pump that can adapt in response to changes in a patient's physiology.

摘要

血流波形是HeartWare心室辅助装置(HVAD)的一个重要特征,它能提供有关HVAD功能和患者血流动力学的信息。我们评估了波形一个特定方面的特性,即心室充盈期(VFP)的斜率,及其与肺毛细血管楔压(PCWP)的相关性。在有创血流动力学递增研究的连续阶段,同时获取了101张来自HVAD监测器的截图以及同步的血流动力学测量数据。每张截图都进行了数字化处理(IGOR Pro,WaveMetrics公司,俄勒冈州奥斯威戈),并分析了血流波形的特性,包括瞬时血流和血流变化率。计算了每张截图的心室充盈期斜率(VFPS),并将其与PCWP进行关联。PCWP≥18 mmHg的患者心室充盈期斜率显著高于PCWP<18 mmHg的患者[6.25(5.84 - 7.37)L/min/s对3.27(2.00 - 4.69)L/min/s,p≤0.0001]。VFPS阈值为5.8 L/min/s时,预测PCWP≥18 mmHg的敏感性为87%,特异性为95%(曲线下面积0.95)。HVAD血流波形的心室充盈期斜率是一个新的无创参数,与PCWP相关,能够区分PCWP升高与正常或降低的情况。自动报告该参数可能有助于对接受HVAD支持的患者进行临床评估和管理,并可能作为智能LVAD泵的基础,该泵能够根据患者生理变化进行自适应调整。

相似文献

2
HVAD Flow Waveform Estimates Left Ventricular Filling Pressure.
J Card Fail. 2020 Apr;26(4):342-348. doi: 10.1016/j.cardfail.2020.01.012. Epub 2020 Jan 23.
3
Echocardiographic Predictors of Hemodynamics in Patients Supported With Left Ventricular Assist Devices.
J Card Fail. 2018 Sep;24(9):561-567. doi: 10.1016/j.cardfail.2018.07.004. Epub 2018 Jul 24.
4
Pulmonary Capillary Wedge Pressure Patterns During Exercise Predict Exercise Capacity and Incident Heart Failure.
Circ Heart Fail. 2018 May;11(5):e004750. doi: 10.1161/CIRCHEARTFAILURE.117.004750.
5
Unrecognized Left Heart Failure in LVAD Recipients: The Role of Routine Invasive Hemodynamic Testing.
ASAIO J. 2018 Mar/Apr;64(2):183-190. doi: 10.1097/MAT.0000000000000617.
6
Usefulness of pulmonary capillary wedge pressure as a correlate of left ventricular filling pressures in pulmonary arterial hypertension.
J Heart Lung Transplant. 2014 Feb;33(2):157-62. doi: 10.1016/j.healun.2013.10.008. Epub 2013 Oct 11.

引用本文的文献

2
Implantable hemodynamic monitoring and management of left ventricular assist devices: Optimal or optional?
JTCVS Open. 2021 Sep 24;8:18-23. doi: 10.1016/j.xjon.2021.09.026. eCollection 2021 Dec.
4
Physiology and Clinical Utility of HeartMate Pump Parameters.
J Card Fail. 2022 May;28(5):845-862. doi: 10.1016/j.cardfail.2021.11.016. Epub 2021 Dec 31.
5
Implication of Hemodynamic Assessment during Durable Left Ventricular Assist Device Support.
Medicina (Kaunas). 2020 Aug 15;56(8):413. doi: 10.3390/medicina56080413.
6
Advances in Hemodynamic Monitoring in Heart Failure Patients.
Intern Med. 2021 Jan 15;60(2):167-171. doi: 10.2169/internalmedicine.4615-20. Epub 2020 Jun 2.
7
Physiology of the Assisted Circulation in Cardiogenic Shock: A State-of-the-Art Perspective.
Can J Cardiol. 2020 Feb;36(2):170-183. doi: 10.1016/j.cjca.2019.11.002. Epub 2019 Nov 9.
8
HVAD Flow Waveform Estimates Left Ventricular Filling Pressure.
J Card Fail. 2020 Apr;26(4):342-348. doi: 10.1016/j.cardfail.2020.01.012. Epub 2020 Jan 23.
9
Continuous LVAD monitoring reveals high suction rates in clinically stable outpatients.
Artif Organs. 2020 Jul;44(7):E251-E262. doi: 10.1111/aor.13638. Epub 2020 Mar 1.
10
Estimation of the Severity of Aortic Insufficiency by HVAD Flow Waveform.
Ann Thorac Surg. 2020 Mar;109(3):945-949. doi: 10.1016/j.athoracsur.2019.09.077. Epub 2019 Nov 19.

本文引用的文献

2
Hemodynamic Ramp Tests in Patients With Left Ventricular Assist Devices.
JACC Heart Fail. 2016 Mar;4(3):208-17. doi: 10.1016/j.jchf.2015.10.001. Epub 2015 Dec 30.
3
Hemodynamics of Mechanical Circulatory Support.
J Am Coll Cardiol. 2015 Dec 15;66(23):2663-2674. doi: 10.1016/j.jacc.2015.10.017.
4
Seventh INTERMACS annual report: 15,000 patients and counting.
J Heart Lung Transplant. 2015 Dec;34(12):1495-504. doi: 10.1016/j.healun.2015.10.003. Epub 2015 Oct 8.
5
Accuracy of the HVAD Pump Flow Estimation Algorithm.
ASAIO J. 2016 Jan-Feb;62(1):15-9. doi: 10.1097/MAT.0000000000000295.
7
Medical management of patients with continuous-flow left ventricular assist devices.
Curr Treat Options Cardiovasc Med. 2014 Feb;16(2):283. doi: 10.1007/s11936-013-0283-0.
9
Use of an intrapericardial, continuous-flow, centrifugal pump in patients awaiting heart transplantation.
Circulation. 2012 Jun 26;125(25):3191-200. doi: 10.1161/CIRCULATIONAHA.111.058412. Epub 2012 May 22.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验