Suppr超能文献

在猪模型中对喉返神经附近使用超声能量的安全性评估。

Safety assessment of the use of ultrasonic energy in the proximity of the recurrent laryngeal nerve in a porcine model.

作者信息

Chávez Karla V, Barajas Elpidio M, Soroa Francisco, Gamboa-Dominguez Armando, Ordóñez Samuel, Pantoja Juan P, Sierra Mauricio, Velázquez-Fernández David, Herrera Miguel F

机构信息

Service of Endocrine Surgery, Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán, Mexico City, Mexico.

Service of Otolaryngology, Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán, Mexico City, Mexico.

出版信息

Am J Surg. 2018 Jan;215(1):186-190. doi: 10.1016/j.amjsurg.2017.04.013. Epub 2017 Jun 7.

Abstract

BACKGROUND

Advanced bipolar and ultrasonic energy have demonstrated reduction of operating time and blood loss in thyroidectomy. However, these devices generate heat and thermal dispersion that may damage adjacent structures such as the recurrent laryngeal nerve (RLN). This study was designed to evaluate the safety profile of the Harmonic Focus+ (HF+) device through the evaluation of thermal injury to the RLN using different algorithms of distance and time with state of the art technology.

METHODS

25 Vietnamese pigs underwent activation of HF+ in the proximity of their RLN. They were divided into 4 groups according to activation distance (3 mm, 2 mm, 1 mm and on the RLN). Time of activation, time between tones of the ultrasonic generator, changes in the electromyographic signal using continuous nerve neuromonitoring, vocal fold mobility assessed by direct laryngoscopy and histological thermal damaged were evaluated.

RESULTS

None of the pigs had loss of signal in the electromyography during the procedure; only one pig had isolated transient decrease in amplitude and one increase in latency. One pig had transient vocal fold paresis in the group with activation on the nerve. Evaluation of the nerves by histology and immunohistochemistry did not show significant changes attributed to thermal injury.

CONCLUSIONS

The use of ultrasonic energy close to the RLN is safe, provided that activation time does not exceed the necessary time to safely transect the tissue.

摘要

背景

先进的双极和超声能量已证明可减少甲状腺切除术中的手术时间和出血量。然而,这些设备会产生热量和热扩散,可能会损伤诸如喉返神经(RLN)等邻近结构。本研究旨在通过使用先进技术,采用不同的距离和时间算法评估对RLN的热损伤,来评估Harmonic Focus+(HF+)设备的安全性。

方法

25头越南猪在其RLN附近激活HF+。根据激活距离(3毫米、2毫米、1毫米以及在RLN上)将它们分为4组。评估激活时间、超声发生器音调之间的时间、使用连续神经神经监测的肌电信号变化、通过直接喉镜检查评估的声带活动度以及组织学热损伤情况。

结果

在手术过程中,没有猪的肌电图信号丢失;只有一头猪出现孤立的短暂幅度下降和一次潜伏期增加。在神经上进行激活的组中有一头猪出现短暂的声带麻痹。通过组织学和免疫组织化学对神经的评估未显示出因热损伤导致的显著变化。

结论

只要激活时间不超过安全切断组织所需的时间,在RLN附近使用超声能量是安全的。