Suppr超能文献

轻度运动心率动态变化:对用S形函数和指数函数拟合的数据的比较以及体能和运动强度的影响。

Light exercise heart rate on-kinetics: a comparison of data fitted with sigmoidal and exponential functions and the impact of fitness and exercise intensity.

作者信息

Trounson Karl M, Roberts Spencer, Balloch Aaron, Warmington Stuart A

机构信息

Institute for Physical Activity and Nutrition, School of Exercise and Nutrition Sciences, Deakin University, Burwood, Victoria, Australia.

School of Medical and Health Sciences, Edith Cowan University, Perth, Western Australia.

出版信息

Physiol Rep. 2017 Jun;5(12). doi: 10.14814/phy2.13312.

Abstract

This study examined the suitability of sigmoidal (SIG) and exponential (EXP) functions for modeling HR kinetics at the onset of a 5-min low-intensity cycling ergometer exercise test (5MT). The effects of training status, absolute and relative workloads, and high versus low workloads on the accuracy and reliability of these functions were also examined. Untrained participants (UT;  = 13) performed 5MTs at 100W. One group of trained participants ( = 10) also performed 5MTs at 100W (ET). Another group of trained participants ( = 9) performed 5MTs at 45% and 60% V˙O2 max (ET and ET, respectively). SIG and EXP functions were fitted to HR data from 5MTs. A 30-s lead-in time was included when fitting SIG functions. Functions were compared using the standard error of the regression (SER), and test-retest reliability of curve parameters. SER for EXP functions was significantly lower than for SIG functions across all groups. When residuals from the 30-s lead-in time were omitted, EXP functions only outperformed SIG functions in ET (EXP, 2.7 ± 1.2 beats·min; SIG, 3.1 ± 1.1 beats·min:  < 0.05). Goodness of fit and test-retest reliability of curve parameters were best in ET and comparatively poor in UT Overall, goodness of fit and test-retest reliability of curve parameters favored functions fitted to 5MTs performed by trained participants at a high and relative workload, while functions fitted to data from untrained participants exercising at a low and absolute workload were less accurate and reliable.

摘要

本研究考察了S形(SIG)和指数(EXP)函数对5分钟低强度自行车测力计运动试验(5MT)开始时心率动力学建模的适用性。还研究了训练状态、绝对和相对工作量以及高负荷与低负荷对这些函数准确性和可靠性的影响。未经训练的参与者(UT;n = 13)以100W进行5MTs测试。一组训练有素的参与者(n = 10)也以100W进行5MTs测试(ET)。另一组训练有素的参与者(n = 9)分别以45%和60%的最大摄氧量进行5MTs测试(分别为ET和ET)。将SIG和EXP函数拟合到5MTs的心率数据中。拟合SIG函数时包含30秒的导入时间。使用回归标准误差(SER)和曲线参数的重测信度对函数进行比较。在所有组中,EXP函数的SER显著低于SIG函数。当省略30秒导入时间的残差时,EXP函数仅在ET组中优于SIG函数(EXP,2.7±1.2次·分钟;SIG,3.1±1.1次·分钟:P<0.05)。曲线参数的拟合优度和重测信度在ET组中最佳,在UT组中相对较差。总体而言,曲线参数的拟合优度和重测信度有利于由训练有素的参与者在高相对工作量下进行的5MTs拟合的函数,而由未经训练的参与者在低绝对工作量下运动的数据拟合的函数准确性和可靠性较低。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/e715/5492202/51892147f2ae/PHY2-5-e13312-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验