Abstract

The 2013 ISTH-SSC guidelines for the standardization of light transmission aggregometry (LTA) were largely based on expert consensus, as studies directly comparing LTA methodologies were lacking. We experimentally tested the cogency of ISTH-SSC recommendations pertaining to use of anticoagulant, in particular whether: (1) buffered citrate (BC) is preferable to unbuffered citrate (C); (2) the two recommended concentrations of sodium citrate (109 and 129 mM) are equivalent in terms of platelet aggregation (PA). Blood from 16 healthy volunteers was collected into BC and C (109 and 129 mM). PA was measured by LTA in platelet-rich plasma (PRP) stimulated by adenosine diphosphate (ADP) (2 μM) immediately after PRP preparation and up to 4 hr after blood collection; pH and platelet counts in PRP were measured in parallel. pH in PRP increased with time up to about 8 for all anticoagulants, although it was lower in BC than in C at all times. In BC, PA was lower at 45 min, but equivalent at all other times. PA was higher and more stable in sodium citrate 109 mM than in 129 mM at all times. The extent of PA did not change for up to 2 hr after blood collection, and subsequently dramatically decreased. In contrast with ISTH-SSC recommendations, (1) BC does not show advantages compared to C; (2) 109 mM citrate is preferable to 129 mM, because it better supports PA; and (3) LTA studies should be completed within 2 hr of blood collection, instead of the recommended 4 hr.

摘要

2013 年 ISTH-SSC 关于光传输聚集测定(LTA)标准化的指南主要基于专家共识,因为缺乏直接比较 LTA 方法学的研究。我们通过实验检验了 ISTH-SSC 关于抗凝剂使用的建议的合理性,特别是:(1)缓冲柠檬酸盐(BC)是否优于未缓冲柠檬酸盐(C);(2)两种推荐的柠檬酸钠浓度(109 和 129mM)在血小板聚集(PA)方面是否等效。将来自 16 名健康志愿者的血液分别采集到 BC 和 C(109 和 129mM)中。在 PRP 制备后即刻以及采血后 4 小时内,用 LTA 测量富含血小板的血浆(PRP)在二磷酸腺苷(ADP)(2μM)刺激下的 PA;同时平行测量 PRP 中的 pH 值和血小板计数。所有抗凝剂的 PRP pH 值随时间增加至约 8,但 BC 的 pH 值始终低于 C。在 BC 中,45 分钟时 PA 较低,但在所有其他时间等效。在所有时间点,109mM 柠檬酸钠的 PA 更高且更稳定。采血后 2 小时内 PA 程度没有变化,随后急剧下降。与 ISTH-SSC 建议相反,(1)BC 与 C 相比没有优势;(2)109mM 柠檬酸盐优于 129mM,因为它更好地支持 PA;(3)LTA 研究应在采血后 2 小时内完成,而不是推荐的 4 小时。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验