In this study, analytic performance (imprecision, carryover, time stability) and diagnostic efficiency of Mindray BC-6800 analyzer to quantify reticulocytes and extended reticulocyte parameters was evaluated. Moreover, reference intervals on adult population were determined. Results were compared with those obtained by Sysmex XE-5000 analyzer.
One hundred and eighty-four healthy adults of both sexes, and 368 subjects affected by various pathologic conditions (nutritional anemias before and after treatment, hemolytic and posthemorragic anemias, acute and chronic inflammations, malignancy under therapy, and beta thalassemia trait) were selected.
Reference intervals were as follows: reticulocytes (×10 /L): 23.2-93.2; immature reticulocyte fraction: 0.015-0.14; mean reticulocyte hemoglobin equivalent (RHE) (pg): 30.9-35.7; mean reticulocyte volume (fL): 97.8-118. Imprecision on reticulocyte count at all concentrations was close to analytic goal based on within-subject biological variation. Carryover (2.3%) was negligible, and time-stability was excellent up to 8 hours.
When compared with XE-5000, BC-6800 shows a good overall correlation on counting despite evidence of difference in the upper limit of reference intervals (93.2 vs 101.3). Comparison of diagnostic efficiency of extended parameters shows a good total agreement of RHE (91.6%).
在本研究中,评估了迈瑞BC - 6800分析仪定量网织红细胞及扩展网织红细胞参数的分析性能(不精密度、携带污染、时间稳定性)和诊断效率。此外,还确定了成人人群的参考区间。将结果与Sysmex XE - 5000分析仪获得的结果进行比较。
选取184名健康成年男女以及368名患有各种病理状况的受试者(治疗前后的营养性贫血、溶血性和失血性贫血、急慢性炎症、接受治疗的恶性肿瘤以及β地中海贫血特征)。
参考区间如下:网织红细胞(×10⁹/L):23.2 - 93.2;未成熟网织红细胞比例:0.015 - 0.14;平均网织红细胞血红蛋白含量(RHE)(pg):30.9 - 35.7;平均网织红细胞体积(fL):97.8 - 118。基于受试者内生物学变异,所有浓度下网织红细胞计数的不精密度接近分析目标。携带污染率(2.3%)可忽略不计,且长达8小时的时间稳定性极佳。