Sáez María Del M, López Gabriela L, Atlas Diana, de la Casa María L
Universidad Nacional de Tucumán, Facultad de Odontología, Cátedra de Práctica Final Obligatoria. Tucumán, Argentina.
Universidad Nacional de Tucumán, Facultad de Odontología, Cátedra de Endodoncia, Tucumán, Argentina.
Acta Odontol Latinoam. 2017 Apr;30(1):26-32.
The aim of this ex vivo study was to evaluate changes in pH and calcium ion diffusion through root dentin from calcium hydroxide (Ca (OH) ) and mineral trioxide aggregate (MTA) pastes at 7, 30 and 60 days; and the relationship between pH and ion diffusion. Thirty-two human premolars were used. Crowns were sectioned and root canals instrumented and filled in with the following preparations: 1) Ca(OH) + distilled water (n=7); 2) Ca(OH) + 0.1% chlorhexidine gluconate (n=7); 3) MTA + distilled water (n=7); 4) MTA + 0.1% chlorhexidine gluconate (CHX) (n=7); 5) distilled water (n=2) (control); 6) 0.1% chlorhexidine gluconate (n=2) (control). The apex and coronary opening were sealed with IRM. Roots were placed in Eppendorf tubes with 1 ml distilled water at 37°C and 100% humidity. At baseline, 7, 30 and 60 days, pH was measured with pH meter, and calcium ion content in the solution was analyzed by atomic absorption spectrophotometry. The data were statistically analyzed using ANOVA, simple linear regression analysis and Pearson's correlation test. The highest pH values were achieved with calcium hydroxide pastes at 60 days (p ≤ 0.05). Calcium ions were released in all groups. The calcium hydroxide paste with distilled water at 60 days had the highest calcium ion value (p ≤ 0.01). There was a positive correlation between calcium and pH values.
本体外研究的目的是评估在7天、30天和60天时,通过氢氧化钙(Ca(OH)₂)糊剂和三氧化矿物凝聚体(MTA)糊剂的牙根牙本质的pH值变化和钙离子扩散情况;以及pH值与离子扩散之间的关系。使用了32颗人类前磨牙。将牙冠切断,预备根管并充填以下制剂:1)Ca(OH)₂ + 蒸馏水(n = 7);2)Ca(OH)₂ + 0.1%葡萄糖酸氯己定(n = 7);3)MTA + 蒸馏水(n = 7);4)MTA + 0.1%葡萄糖酸氯己定(CHX)(n = 7);5)蒸馏水(n = 2)(对照组);6)0.1%葡萄糖酸氯己定(n = 2)(对照组)。根尖和冠部开口用IRM封闭。将牙根置于含有1 ml蒸馏水的Eppendorf管中,温度为37°C,湿度为100%。在基线、7天、30天和60天时,用pH计测量pH值,并用原子吸收分光光度法分析溶液中的钙离子含量。数据采用方差分析、简单线性回归分析和Pearson相关检验进行统计学分析。60天时氢氧化钙糊剂的pH值最高(p≤0.05)。所有组均有钙离子释放。60天时含蒸馏水的氢氧化钙糊剂的钙离子值最高(p≤0.01)。钙离子和pH值之间存在正相关。